Page 10
Shuttle Brewers & Airpot/Shuttle Brewers
Programming (cont.)
13)
By-PASS
(Set bypass volume):
Choose
OFF
to
25%
Set the amount of bypass desired during brew. If none is desired
then set to OFF, otherwise, set the % of brew volume to bypass.
14)
CoPY-to-LEFt
:
Choose
YES
or
no
If the same program parameters are desired on same portion size
on the left side, then choose
YES
and the parameters will
be copied.
The sequence of programming for the Medium portion is as follows:
(refer to Table 2)
1)
Br time
(Brew time):
Choose
0:01
-
6:00
minutes
2)
PrE inFuSion
:
Choose
OFF
to
2:00
minutes
3)
PrE inFuSion oFF
:
Choose
0:05
to
2:00
minutes
4)
PuLSE br
(Pulse Brewing):
Choose
OFF
to
10
5)
PuLSE on
(Pulse ON time):
Choose
0:05
-
2:00
minutes
6)
PuLSE oFF
(Pulse OFF time):
Choose
0:05
-
2:00
minutes
7)
By-PASS
(Set bypass volume):
Choose
OFF
-
25%
8)
CoPY-to-LEFt
: Choose
YES
or
no
The sequence of programming for the Small portion is as follows:
(refer to Table 3)
1)
Br time
(Brew time):
Choose
0:01
-
6:00
minutes
2)
PrE inFuSion
:
Choose
OFF
to
2:00
minutes
3)
PrE inFuSion oFF
:
Choose
0:05
to
2:00
minutes
4)
PuLSE br
(Pulse Brewing):
Choose
OFF
to
10
5)
PuLSE on
(Pulse ON time):
Choose
0:05
-
2:00
minutes
6)
PuLSE oFF
(Pulse OFF time):
Choose
0:05
-
2:00
minutes
7)
CoPY-to-LEFt
: Choose
YES
or
no