Model LCD-2R and LCD-2A
Introduction
The Grindmaster-Cecilware Liquid Coffee Dispensers (LCD-2A) and the Liquid Coffee Chilled Dispenser
(LCD-2R) deliver two types of coffee made from liquid concentrate plus hot water.
• The dispenser can be set up for continuous draw (by the cup) for self-serve applications, or portion-control
to fill carafes and decanters for wait staff. The standard machine allows for (2) portion sizes per dispense
head with the use of a hidden override switch located on the bottom left side of the door. If the override
switch is pushed, the user has (10) seconds to activate a switch to achieve the override portion setting
programmed for that dispense head. Optionally, the machine can be fitted with 2 portion touchpads.
• Follow the concentrate manufacturer’s storage and shelf life recommendations. Product flavor profile is
extended with chilled product storage cabinet featured in the LCD-2R.
• The refrigerated model LCD-2R incorporates a Solid State Thermoelectric cooling system which requires
little maintenance. Cleaning of the thermoelectric may be required on a periodic basis depending on the air
quality of the loaction and should be performed only by a qualified technician.
• This dispenser is designed to operate when the ambient temperatures are from 32°F (0°C) minimum to
86°F (30°C) maximum. Do not allow machine to operate or be stored below freezing temperatures or
permanent damage will occur to machine unless water has been purged from all water lines.