9 (16) • No: 90 072 01 Rev 1 2005.07
When the pump has been in use for a long time,
the compression of the rubber cable seal might be
diminished, which can cause leakage. By screwing-in
the cable entry the seal will be retensioned.
Bravo 20, 30, 40
• Unscrew the 2 hexagon socket screws (1).
• Remove the cable clamp (2).
• Turn the hexagon head of the entry (3) clockwise,
using the right tool, so far that it is possible to replace
the cable clamp again.
• Screw-in the 2 hexagon socket screws (1).
It is possible that your pump is fitted with only 1 cable.
Bravo 50, 60
• Unscrew the 4 hexagon socket screws (1) from the
outer cable entries.
• Remove the cable clamps (2).
• Turn the hexagon heads of the entry clockwise, using
the right tool, so far that it is possible to replace the
cable clamps again.
• Screw-in the 4 hexagon socket screws (1).
It is possible that your pump is fitted with only 1 cable.
Cable entry