Box 538 S-136 25 Haninge SWEDEN www.grindex.com
U
Before use see
operators manual
Ø 3
I
c/s
~
TYPE
NETHERLAND
S
kW
MADE IN TH
E
Pmax
V
Qmax
Hz
20m
Hmax
A
l/s
m
No
kg
Model
Pump type No.
Rated voltage
Rated current
Number of phases
and frequency
Serial No.
Weight
Maximum power consumption
Maximum pressure head
Maximum flow capacity
Maximum submersion depth
accordance with
technical data
external motor
protection in
This pump must
be used with
Start reaction
Rotation
3 (16) • No: 90 072 01 Rev 1 2005.07
How to read the data plates
If you need further technical data please refer to the
relevant data sheets.
Safety Precautions.
All electrical work should be performed by an authorized electrician. Follow local safe-
ty regulations and observe recommended safety precautions.
All electrical equipment must be earthed. This applies to both pump and equipment.
Before starting work on the pump, make sure that the pump is isolated from the power
supply and can not be energized. Be sure to disconnect the power supply before attempt-
ing inspection, as pump may start automatically. Respect limitations, see page 6.
Attention!
Before the pump is installed in the sump check the
direction of rotation. Start reaction is counter clock-
wise and rotation of motor is clock-wise when the
pump is viewed from top. See arrows on data plate of
pump.
WARNING!
The start reaction of motor can be powerful!
Installation and use
Read this manual before installing the pump.
Check that you have received the right type of pump and that the pump data corresponds
with what you ordered. The simplest way to do this is to check the particulars on the data
plate, which you will find on the pump. The rated voltage, rated current and maximum
power consumption are particularly important. On the bases of these particulars you should
check that you have the right power supply, motor controller and fuse arrangement.