4. Click the OK button when finished.
3.1.3 Static IP Address Configuration
To manually assign an IP address and its network configuration:
1. Click Network from the main menu.
2. Select
Use the following IP configuration
.
3. Enter the following (as necessary):
IP Address
If DHCP is not used to assign IP addresses, enter it manually. The IP address
must be set to a unique value in the network.
Subnet Mask
A subnet mask defines the number of bits taken from the IP address that are
assigned for the host part.
Default Gateway
The gateway address, or router, allows communication to other LAN segments.
The gateway address should be the IP address of the router connected to the
same LAN segment as the unit. The gateway address must be within the local
network.
4. Click the
OK
button when finished.
3.1.4 Ethernet Configuration
You must specify the speed and direction of data transmission.
To specify how data will be transmitted:
1. On the main menu, click
Network
.
2. Enter the following (as necessary):
Auto Negotiate
With this option, the Ehernet port auto-negotiates the speed and duplex
with the hardware endpoint to which it is connected. This is the default.
If this option is not selected, the complete the fields that become
available:
Speed:
The speed of data transmission. The default is
100 Mbps.
Duplex:
The direction of data transmission. The default is
Full.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Wi232/WiUSB User Guide