![GridConnect NET232 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/gridconnect/net232/net232_user-manual_2264799018.webp)
Overview
2.11 Technical Specifications
Table 4 - Technical Specs
Category
Description
CPU
DSTni-EX 186 CPU
Firmware
Upgradeable via TFTP and serial port
Reset Circuit
200msec power up/down reset pulse. Reset triggered at 3.08V
Serial Interface
RS232. Baudrate software selectable (300 to 230400bps in standard mode, 460800 and
921600 in high performance mode)
USB
USB Type A Male connector. USB Specification 2.0 Compliant, Full Speed (12Mbps).
Baud rates: 300bps to 921.6Kbps.
512 Byte Receive Buffer, 512 Byte Transmit Buffer.
Virtual COM Port Device Drivers for Win 98/2000/XP, Win CE, Linux 2.40
Serial Line Formats
7 or 8 data bits, 1-2 Stop bits, Parity: odd, even, none
Modem Control
CTS, RTS
Flow Control
XON/XOFF (software), CTS/RTS (hardware), None
Network Interface
RJ45 Ethernet 10Base-T or 100Base-TX (Auto-sensing)
Compatibility Ethernet:
Version 2.0/IEEE 802.3
Protocols Supported
ARP, UDP/IP, TCP/IP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, Auto IP, SMTP,
and HTTP
LEDs
10Base-T & 100Base-TX Activity, Full/half duplex.
Management
Internal web server, SNMP (read only)
Serial login, Telnet login
Security
Password protection, Locking features, optional Rijndael 128-bit encryption
Internal Web Server
Serves static web pages and Java applets
Weight
2.2oz
Material Case:
Flame Retardant
Temperature
Operating range: -40°C to +85°C (-40°F to 185°F) High performance mode has an
upper temperature limit of 75°C.
Relative Humidity
Operating: 5% to 95% non-condensing
Warranty 1-year
limited
warranty
Included Software
Windows™ 98/NT/2000/XP based Device Installer configuration software, Windows™
based Comm Port Redirector and USB device drivers.
EMI Compliance
Radiated & conducted emissions - complies with Class B limits of EN 55022:1998
Direct & Indirect ESD - complies with EN55024:1998
RF Electromagnetic Field Immunity - complies with EN55024:1998
Electrical Fast Transient/Burst Immunity - complies with EN55024:1998
Power Frequency Magnetic Field Immunity - complies with EN55024:1998
RF Common Mode Conducted Susceptibility - complies with EN55024:1998
2-8
NET232/NETUSB User Guide
Содержание NET232
Страница 1: ...NET232 NETUSB Serial to Ethernet Adapter Revision C July 25 2008 Document Part Number GC 800 232 ...
Страница 2: ......
Страница 56: ......
Страница 58: ......
Страница 62: ......
Страница 65: ...NET232 NETUSB User Guide 6 1 ...