4-36
CAN232 FD User Manual
operating mode, the new filter settings will become active and will be applied to each received CAN
message.
4.12 config filters std #n
The
filters std #n
level contains the detail parameters for standard ID filter #n.
4.12.1 enable <value>
Sets the enable value for this filter to
no
or
yes
.
4.12.2 sid1 <value>
Sets the sid1 value for this filter. Values between 0 and 7FF in hex can be specified.
4.12.3 sid2 <value>
Sets the sid2 value for this filter. Values between 0 and 7FF in hex can be specified.
4.12.4 type <value>
Sets the type for this filter between
range
,
dual
and
classic
.
range: sid1=< ID <= sid2
dual: ID = sid1 or ID = sid2
classic: (Active/1 bits in sid1) = (ID bits in sid2)
Note to create a single ID filter use type range or dual and set sid1=sid2=ID or use type classic and set
sid1=7FF and sid2=ID.
4.12.5 reject <value>
Sets the reject option for this filter to
no
or
yes
for inclusive or exclusive filtering respectively.
4.12.6 limiter <value>
Sets the limiter type for this filter between
none
,
divide
and
frequency
. The
none
selection is the default
and disables the limiter so all messages pass. The divide setting will only pass 1 message out of every
scale
messages. The frequency setting will only pass 1 message every
scale
milliseconds.
config filters std #1>?
show
enable <value>
sid1 <value>
sid2 <value>
type <value>
reject <value>
limiter <value>
scale <value>
exit