CAN232 FD User Manual
4-23
Enter the
export config
command at the prompt. The configuration output will look similar to the
following:
Note: The configuration is stored as simple text and it can be edited, but it is recommended that edits to the
configuration be done on the device for error checking and then use the
export config
command and log to
a new file.
Next, Click Close in the Tera Term: Log window.
>export config
config
{
com
{
baud : 115200
data bits : 8
parity : none
stop : 1
flow : none
mode : command
startup delay : 0
}
can
{
baud : 250000
sample point : 80
timeout : 0
FD : disable
FDbaud : 2000000
.
.
.
type : range
reject : no
limiter : none
scale : 0
}
}
tunnel
{
rxid size : std
rxid : 0
txid size : std
txid : 0
txFD : disable
lenFD : 32
trigger : 0
timer : 20
}
}
>