background image

NDD Series - NO2 Transmitter                                                              

Installation Manual 

 

 
Feb 2, 2016

                            

                          NDD-INS-002 

 

  Page 4 

 
Common Specifications   

Measurement . . . . . . . . . . . . . . . . .  Electrochemical 
Sample Method . . . . . . . . . . . . . . .  Diffusion 
Measurement Range . . . . . . . . . . .  0-10 ppm 
Accuracy . . . . . . . . . . . . . . . . . . . . 

 0.2 ppm or 

 5% of reading (whichever is greater) 

Sensor Life Expectancy . . . . . . . . .  > 2 years  
Operating Temperature  . . . . . . . . .  -20-50 

C (-4 -122 

F),  

Operating Humidity . . . . . . . . . . . . 15-90 %RH (0-99% intermittent) 
Pressure . . . . . . . . . . . . . . . . . . . . .  Atmospheric  

 

10% 

   

Typical Area Coverage . . . . . . . . .  700 m

2

 (7500 ft

2

) or 15 m (50 ft) radius 

Calibration Adjustments . . . . . . . .   Zero and Span pots 
Wiring Connections . . . . . . . . . . .   Screw terminal block (14 to 22 AWG) 
Enclosure . . . . . . . . . . . . . . . . . . .  2.8”w x 4.1”h x 1.9”d (71 x 104 x 48 mm)

 

Power Supply . . . . . . . . . . . . . . . .   24 Vdc ± 20% or 24 Vac ± 10% (non-isolated half-wave rectified) 
Consumption . . . . . . . . . . . . . . . . .  50 mA max 
Output Signal . . . . . . . . . . . . . . . .   4-20 mA sourcing 
Output Drive Capability . . . . . . . .  550 ohms max @ 24 Vac/dc 
Relay Contacts . . . . . . . . . . . . . . .   SPDT, Form C contacts (N.O. and N.C.), 5 Amps @ 30 Vdc 
Relay Trip Point . . . . . . . . . . . . . .  Low = 1 ppm, Mid = 3 ppm or High = 5 ppm,  jumper selectable 
Relay Hysteresis . . . . . . . . . . . . . .  3%  

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание NDD Series

Страница 1: ... measure the NO2 level in the surrounding air and output a proportional value on the 4 20 mA output The NO2 measurement range is 0 to 10 ppm The relay can be used to indicate an alarm condition The trip point for the relay can be programmed to three different settings with an on board jumper If the NO2 level exceeds the trip point then the relay is activated The relay will remain activated until t...

Страница 2: ...and does not require a loop power supply This means the signal current is generated by the transmitter and must not be connected to a powered input or device damage will result This is the typical operating mode of a three wire device Check the controller Analog Input to determine the proper connection before applying power Ensure the controller Analog Input AI matches the transmitter output signa...

Страница 3: ...d directly to the port on the cover and monitor the output signal The device cover must be removed to perform an actual calibration In this case the gas calibration cap attaches to the sensor fixture inside the enclosure The sensor must be continuously powered for at least 1 2 hour prior to calibration Calibrate the sensor either in clean air or by applying Zero gas with a flow rate of 0 5 to 1 li...

Страница 4: ... Pressure Atmospheric 10 Typical Area Coverage 700 m2 7500 ft2 or 15 m 50 ft radius Calibration Adjustments Zero and Span pots Wiring Connections Screw terminal block 14 to 22 AWG Enclosure 2 8 w x 4 1 h x 1 9 d 71 x 104 x 48 mm Power Supply 24 Vdc 20 or 24 Vac 10 non isolated half wave rectified Consumption 50 mA max Output Signal 4 20 mA sourcing Output Drive Capability 550 ohms max 24 Vac dc Re...

Отзывы: