ENCLOSURE INSTALLATION
Locate the enclosure within 20 ft (6 m) of the sensor (500 ft -150 m optional). The enclosure can be wall
mounted with the four mounting screws (included) or panel mounted with Option PM Panel Mount kit
from Greyline Instruments.
Avoid mounting the enclosure in direct sunlight to protect the electronics from damage due to
overheating and condensate. In high humidity atmospheres, or where temperatures fall below freezing,
Option TH Enclosure Heater and Thermostat is recommended. Seal conduit entries to prevent moisture
from entering enclosure.
NEMA4X (IP66) WITH CLEAR COVER
1. Open hinged enclosure cover.
2. Insert #12 screws (supplied) through the four enclosure mounting holes
to secure the enclosure to the wall or mounting stand.
Additional conduit holes can be cut in the bottom of the enclosure when
required. Use a hole saw or Greenlee-type hole cutter to cut the required
holes.
DO NOT make conduit/wiring entries into the top of the enclosure.
Note: This non-metallic enclosure does not automatically provide
grounding between conduit connections. Grounding must be provided as part of the installation. Ground
in accordance with the requirements of the National Electrical Code. System grounding is provided by
connecting grounding wires from all conduit entries to the steel mounting plate or another point which
provides continuity.
CLEANING
Cleaning is not required as a part of normal maintenance.
Содержание OCF 5.0
Страница 2: ...Note This page has been left blank intentionally ...
Страница 5: ...Page 5 OCF 5 0 Open Channel Flow Monitor CONNECTIONS ...
Страница 7: ...Page 7 OCF 5 0 Open Channel Flow Monitor CALIBRATION MENU ...
Страница 8: ...Page 8 OCF 5 0 Open Channel Flow Monitor ICONS ...
Страница 14: ...Page 14 OCF 5 0 Open Channel Flow Monitor CHANNEL SETUP ...
Страница 20: ...Page 20 OCF 5 0 Open Channel Flow Monitor SENSOR MOUNTING METHODS ...
Страница 33: ...Page 33 OCF 5 0 Open Channel Flow Monitor EXTENDED SENSOR CABLE INSTALLATION IN MANHOLE ...
Страница 35: ...Page 35 OCF 5 0 Open Channel Flow Monitor ...
Страница 41: ......