 Operating Manual GMH 5130 

page 7 of 14 

 

 

_____________________________________________________ 

_____________________________________________________________________________ 

 

5  Start Operation 

Connect sensors, turn device on via 

 key. 

After segment test 

 

 

the device displays some configuration: 

 

if standard measurement is selected 

 

if fast measurement is selected 

 

if peak value detection is selected 

After that the device is ready for measuring. 
 

6  Configuration 

 

Some menu points depend on current device settings.   

To change device settings, press 

“menu”

 

 for 2 seconds. This will activate the configuration menu (main 

display:  “SEt”). Pressing 

“menu”

 

 changes between the menus points, pressing 

 jumps to the 

referring parameters, which can be selected with key 

The parameters can be changed with 

 or 

.  

Pressing 

“menu”

 

 

 again jumps back to the main configuration menu and saves the settings. 

“enter”

 

 finishes the configuration and returns to standard measuring operation. 

Pressing “menu” and “store” at the same time for more than 2 seconds will reset the device 
to factory defaults. 
If no key is pressed for more than 2 minutes the configuration will be aborted. All changes 
will not be saved! 

Menu 

Parameter 

Value 

Description

 

 

 

 

 or 

 

 

 

 

 

Set Configuration:  General configurations

 

 

 

Unit: Select measuring unit

 

** 

Arrow to 

bar, 

mbar …

 

Measuring value is displayed in corresponding unit, the selectable units 
depend on connected sensor  

Arrow to 

“user” 

Measuring value is displayed in freely adjustable user-unit  

 

bar, mbar 

Unit “user”: base unit  

 

0000, 000.0, 
…  .0000“ 

Unit “user”: decimal point setting (only if user-unit selected)  

 

-19999...19999 

Unit “user”: multiplication factor 

 

Sea Level: Sea-level correction 

** 

 

oFF 

Sea-level correction off 

on 

Sea-level correction on 

(p.r.t. 7.4)

 

 

-2000 ... 9999

 

Sea-level in [m]  

** 

 

Rate: Measuring rate 

Slo 

Slow

 measuring rate (4 Hz filtered, low power consumption) 

FASt 

Fast

 measuring rate, filtered (1000 Hz)

 

 

P.dEt 

Peak detection

: fast measuring rate, unfiltered (1000 Hz)

 

 

 

Содержание GMH 5130

Страница 1: ...49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de WEEE Reg Nr DE 93889386 as of version 1 0 GMH 5130 Operating Manual Handheld Pressure Meter water proof Please carefully read these instructions b...

Страница 2: ...LEMENTS 5 4 2 PUSHBUTTONS 5 4 3 CONNECTIONS 5 4 4 POP UP CLIP 6 5 START OPERATION 7 6 CONFIGURATION 7 7 REMARKS TO SPECIAL FEATURES 8 7 1 DIFFERENT PRESSURE UNITS 8 7 2 DIFFERENT KINDS OF MEASURING 8...

Страница 3: ...to be observed The device must be used only according to its intended purpose and under suitable conditions Use the device carefully and according to its technical data do not throw it strike it Prot...

Страница 4: ...e usage of this device at potentially explosive areas increases danger of deflagration explosion or fire due to sparking 3 Product Specification 3 1 Scope of supply The scope of supply includes GMH 51...

Страница 5: ...ase refer to chapter 7 1 7 corr arrow zero point or slope correction is active 4 2 Pushbuttons On off key backlight press shortly activate backlight or switch on instrument press longer switch off ins...

Страница 6: ...to swing open the pop up clip further Pop up clip closed Pop up clip at position 90 Pop up clip at position 180 Function The device with a closed pop up clip can be plainly laid onto a table or attac...

Страница 7: ...es the settings enter finishes the configuration and returns to standard measuring operation Pressing menu and store at the same time for more than 2 seconds will reset the device to factory defaults...

Страница 8: ...sor dep e g 5 00 5 00 mbar The offset of sensor will be displaced by this value to compensate for deviations of the probe or of the measuring device Slope adjustment of sensors oFF No slope adjustment...

Страница 9: ...ing tube connection for lower press in contact to ambient air by means of a tube no water contact and bring the sensor with its open pressure connection for higher pressure to water depth to be measur...

Страница 10: ...l net Universal multi channel software for real time recording and displaying of measuring data with real database In case you want to develop your own software we offer a GMH3000 development package...

Страница 11: ...o G1 2 pressure terminal or plug plastic tube to a suitable adapter Connection to instrument Use cable MSD K51 11 Accuracy Check Adjustment Service You can send the device to the manufacturer for adju...

Страница 12: ...h to be displayed Err 4 Display range underflow Check value below 19999 Tara to low Er 11 Value could not be calculated Choose different unit Calculation overflow happened Choose different unit Err 7...

Страница 13: ...ment display illuminated white Correction function offset slope via menu if offset slope value not equal zero corr is displayed Additional functions min max hold function Averaging adjustable 1 120 se...

Страница 14: ...H82 0 01 6C 02 Operating Manual GMH 5130 page 14 of 14 _____________________________________________________ _____________________________________________________________________________...

Отзывы: