GREISINGER GMH 3710 Скачать руководство пользователя страница 1

H49.0.01.6C-03

Operating Manual Precision Thermometer

GMH 3710

 from Version 1.0

For Pt100 4-Wire Temperature Probes

1

IN GENERAL............................................................................................................................................................................ 1

1.1

S

AFETY 

I

NSTRUCTIONS

......................................................................................................................................................... 1

1.2

H

OW TO 

O

PERATE 

A

ND 

M

AINTAIN 

D

EVICE

.......................................................................................................................... 2

1.3

C

ONNECTIONS

...................................................................................................................................................................... 2

1.4

D

ISPLAY 

E

LEMENTS

............................................................................................................................................................. 2

1.5

P

USHBUTTONS

...................................................................................................................................................................... 2

2

DEVICE CONFIGURATION.................................................................................................................................................. 3

2.1

'U

NIT

': S

ELECTION OF 

T

EMPERATURE 

U

NIT 

°C /°F............................................................................................................... 3

2.2

'R

ESOLUTION

': T

HE 

D

ISPLAY 

R

ESOLUTION

........................................................................................................................... 3

2.3

'O

FFSET

': Z

ERO 

D

ISPLACEMENT

........................................................................................................................................... 3

2.4

'S

CAL

': S

CALE 

C

ORRECTION

................................................................................................................................................. 3

2.5

'P

OWER

.

OFF

': S

ELECTION OF 

P

OWER

-O

FF 

D

ELAY

................................................................................................................. 3

2.6

'O

UT

': F

UNCTION OF THE 

O

UTPUT

........................................................................................................................................ 3

2.7

'A

DDRESS

': S

ELECTION OF 

B

ASE 

A

DDRESS WHEN 

O

UTPUT 

= S

ERIAL 

I

NTERFACE

................................................................. 3

2.8

'

D

AC.0V

OLT

': O

UTPUT 

O

FFSET 

W

HEN 

O

UTPUT 

= A

NALOGUE 

O

UTPUT

............................................................................... 3

2.9

'

D

AC.0V

OLT

': O

UTPUT 

S

CALE 

W

HEN 

O

UTPUT 

= A

NALOGUE 

O

UTPUT

................................................................................. 3

3

SOME BASICS OF PRECISION TEMPERATURE MEASURING................................................................................... 4

4

SPECIAL FUNCTIONS ........................................................................................................................................................... 5

4.1

D

ISPLAY 

R

ESOLUTION

.......................................................................................................................................................... 5

4.2

Z

ERO 

D

ISPLACEMENT 

('O

FFSET

').......................................................................................................................................... 5

4.3

S

CALE 

C

ORRECTION 

('S

CALE

').............................................................................................................................................. 5

4.4

O

UTPUT

................................................................................................................................................................................ 5

4.4.1

Interface - Base Address ('Adr.') ................................................................................................................................. 5

4.4.2

Analogue Output – Scaling with DAC.0 and DAC.1................................................................................................... 6

5

FAULT AND SYSTEM MESSAGES...................................................................................................................................... 6

6

CALIBRATION SERVICES.................................................................................................................................................... 6

7

SPECIFICATION ..................................................................................................................................................................... 7

1 In General

1.1 Safety Instructions

This device has been designed and tested in accordance to the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in
this manual will be adhered to when using it.
1. 

Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to any other climatic conditions than those
stated under “Specification”.

2.  If the device is transported from a cold to a warm environment condensation may result in a failure of the function. In such a case make sure

the device temperature has adjusted to the ambient temperature before trying a new start-up.

3.  If device is to be connected to other devices the circuitry has to be designed most carefully. Internal connection in third party devices (e.g.

connection GND and earth) may result in not-permissible voltages impairing or destroying the device or another device connected.

4. 

Warning:

 If device is operated with a defective mains power supply (e.g. short circuit from mains voltage to output voltage) this may result in

hazardous voltages at the device (e.g. at sensor socket)

5.  If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-

starting. Operator safety may be a risk if:

  there is visible damage to the device

  the device is not working as specified

  the device has been stored under unsuitable conditions for a longer time

In case of doubt, please return device to manufacturer for repair or maintenance.

6. 

Warning: 

Do not use these product as safety or emergency stop device, or in any other application where failure of the product could result in

personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material damage.

Содержание GMH 3710

Страница 1: ...free operation and reliability of the device can only be guaranteed if it is not subjected to any other climatic conditions than those stated under Specification 2 If the device is transported from a...

Страница 2: ...e probe the plug will slide in smoothly if plug is entered correctly Selection of Output Mode The output can be used as serial interface or as analogue output This choice has to be done in the configu...

Страница 3: ...measuring will be changed by this factor to compensate for deviations in the temperature probe or in the measuring device factor is in oFF Scale correction factor inactive 0 000 2 5 Power off Selecti...

Страница 4: ...ate very much from the ambient temperature measuring errors often occur if the heat loss caused by the probe is not considered When measuring fluids therefore the probe should be emerged sufficiently...

Страница 5: ...e device can be connected to a PC With the GRS3105 it is possible to connect up to 5 instruments to a single interface please also refer to GRS3105 manual As a precondition the base addresses of all d...

Страница 6: ...r supply if fault continues to exist device damaged low battery voltage replace battery If mains operation wrong voltage Check replace power supply if fault continues to exist device damaged system er...

Страница 7: ...S232 interfaces or analogue output 0 1V freely scaleable resolution 13bit accuracy 0 05 at nominal temperature cap load 1nF Power Supply 9V Battery type IEC 6F22 included as well as additional d c con...

Страница 8: ...H49 0 01 6C 03 Operating Manual GMH 3710 Page 8...

Отзывы: