GE 125 

is a waterproof, universally applicable, durable and low-maintenance gel electrode 
with ceramic diaphragm. It can be immersed above the shaft for an extended time. 

GE 126 

is a extremely low-maintenance and long-term stable gel electrode with ceramic 
diaphragm. 

GE 135 

is a waterproof, universally applicable, durable and low-maintenance gel electrode 
with ceramic diaphragm. It can be immersed above the shaft for an extended time. 

GE 151 

is a glass electrode and is preferably used in galvanic applications for paints and 
lacquers. 

GE 173 

is an alkaline-resistant glass electrode with ground diaphragm and gel electrolyte for 
chemical and waste water applications. 

 

Reshipment and disposal 

6.1  Reshipment 

 

All devices returned to the manufacturer have to be free of any residual of 
measuring media and other hazardous substances. 
Measuring residuals at housing or sensor may be a risk for persons or environment 

 

 

 

 

Use an adequate transport package for reshipment, especially for fully functional 
devices. Please make sure that the device is protected in the package by enough 
packing materials. 

Add the completed reshipment form of the GHM website. 

6.2  Disposal 

 

The device must not be disposed of with household waste. Return it to us, freight 
prepaid. We will then arrange for the proper and environmentally-friendly disposal. 

Private end users in Germany have the possibility of dropping off the product at the 
municipal collection centre. 

 

 

Manufacturer / distributer 

GHM GROUP 

– Greisinger 

GHM Messtechnik GmbH 

Hans-Sachs-Str. 26 

93128 Regenstauf  

Germany 

+49 9402 9383-0  |  

[email protected]

   

www.greisinger.de

 

WEEE-Reg.-Nr.: DE 93889386 

 

Содержание GE 014

Страница 1: ...Z03 0 0X 6C 11 Operating Manual pH electrodes GE xxx Keep for later use www greisinger de Companies Brands of the GHM English...

Страница 2: ...uct for consulting in case of doubt 2 Safety 2 1 Intended Use The pH electrodes must be used only according to its intended purpose and under suitable conditions The electrodes must be operated with s...

Страница 3: ...h can be damaged or destroyed when coming into contact with this chemical Caustic effect protective equipment required This Symbol indicates dangers to all living beings that may result in death or ac...

Страница 4: ...bility cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device The electrodes contain 3 molar KCL GE103 1mol l...

Страница 5: ...specification sheet of chemicals 3 Consider any statutory provisions guidelines and guidelines of chemicals when disposing This is also for accidentally spilled chemicals dried residues soiled rags or...

Страница 6: ...he temperature avoid interference electrostatic charges etc keep plug contacts clean and dry prevent electrodes except special waterproof versions from extended immersion above the shaft calibrate the...

Страница 7: ...ystems 3 4 Service life The service life of electrodes is normally at least 8 to 10 months When cared for properly this can usually increase to more than 2 years The actual life will vary depending on...

Страница 8: ...to 30 C Below 5 C the electrode might be damaged because of freezing of the electrolyte We recommend to store the electrode vertically with the cable to the upper side The pH electrode should be arra...

Страница 9: ...should be avoided as this might damage the electrode permanently Therefore a chemical cleansing is preferable Impurities Cleaners General residue Mild detergent Inorganic coatings common fluids for g...

Страница 10: ...E 100 can be used Some different applications requires a special electrode GE 100 is a universal electrode with two ceramic diaphragms and liquid GE 101 is preferably used for small sample amounts It...

Страница 11: ...disposal 6 1 Reshipment All devices returned to the manufacturer have to be free of any residual of measuring media and other hazardous substances Measuring residuals at housing or sensor may be a ri...

Страница 12: ...Pt1000 sensor pH 0 14 0 60 C 100 S cm max 6 bar 3mol l KCl gel BNC and 4mm banana 2 m pressure resistant up to 6 bar with PG13 5 thread 2x ceramic cylinder PSU approx 12x120 mm GE 120 Cinch injection...

Отзывы: