Greer Company
Greer Company
Greer Company
Greer Company
Crane Systems
1918 EAST GLENWOOD PLACE, SANTA ANA, CA 92705
Tel: (714) 259 9702 Fax: (714) 259 7626
MicroGuard
424 Operation/Troubleshooting Manual Horizontal Display Hydraulic Cranes
31 of 52
W424103 REV A 02/13/01
Fault 3
Fault 3
Fault 3
Fault 3
AAA
B CC
DD
003
0 00
00
Piston pressure transducer
Rod pressure transducer
Fault 4
Fault 4
Fault 4
Fault 4
AAA
B CC
DD
004
0 00
00
Extension
Sensor
Fault 5
Fault 5
Fault 5
Fault 5
AAA
B CC
DD
005
0 00
00
Piston pressure transducer
Extension
sensor
Fault 6
Fault 6
Fault 6
Fault 6
AAA
B CC
DD
006
0 00
00
Rod pressure transducer
Extension
sensor
Rod pressure transducer
Fault 7
Fault 7
Fault 7
Fault 7
AAA
B CC
DD
007
0 00
00
Piston pressure transducer
Rod pressure transducer
Extension
sensor
Fault 8
Fault 8
Fault 8
Fault 8
AAA
B CC
DD
008
0 00
00
Boom angle sensor
Fault 9
Fault 9
Fault 9
Fault 9
AAA
B CC
DD
009
0 00
00
Piston pressure transducer
Boom angle sensor
Fault 10
Fault 10
Fault 10
Fault 10
AAA
B CC
DD
010
0 00
00
Boom angle sensor
Rod pressure transducer
Fault 11
Fault 11
Fault 11
Fault 11
AAA
B CC
DD
009
0 00
00
Boom angle sensor
Piston pressure transducer
Rod pressure transducer
Fault 32
Fault 32
Fault 32
Fault 32
AAA
B CC
DD
032
0 00
00
Swing potentiometer “A”
Fault 64
Fault 64
Fault 64
Fault 64
AAA
B CC
DD
064
0 00
00
Swing potentiometer “B”
Fault 96
Fault 96
Fault 96
Fault 96
AAA
B CC
DD
096
0 00
00
Swing potentiometer “A”
Swing potentiometer “B”
This sequence continues up to the maximum fault code
of
127
that is the sum of all group “A” fault codes.
Fault 127
Fault 127
Fault 127
Fault 127
AAA
B CC
DD
127
0 00
00
All analog sensors.
This fault condition is seldom caused by the
simultaneous failure of all sensors. It is more usually the
result of the failure of the analog drive voltage, which is
the supply voltage for all sensors. This power supply fault
may be due to the failure of the power supply or may be
due to damage to the cable that connects the sensor to
the computer.
When this fault occurs, carry out Power Supply Voltage