Greer Company
Greer Company
Greer Company
Greer Company
Crane Systems
1918 EAST GLENWOOD PLACE, SANTA ANA CA 92705
Tel:(714) 259-9702 Fax:(714) 259-7626
MicroGuard
424 Operation/Troubleshooting Manual Horizontal Display Hydraulic Cranes
Page
22
of
52
W424103 REV A 02/13/01
METHOD OF SETTING
METHOD OF SETTING
METHOD OF SETTING
METHOD OF SETTING
T
HE FOLLOWING EXAMPLES ARE GIVEN TO ILLUSTRATE METHODS OF SETTING ALARMS. THE
ACTUAL VALUES GIVEN SHOULD NOT BE USED WITHOUT FIRST CHECKING THE CAPACITY CHART
TO ENSURE SAFE, STABLE OPERATION UNDER THE CONDITIONS DESCRIBED.
OPERATOR ALARMS WILL BE STORED IN THE COMPUTER MEMORY, EVEN IF THE CRANE IS
SHUTDOWN. THE FOLLOWING PROCEDURES WILL DESCRIBE THE METHOD OF SETTING OR
CANCELING ALARMS.
Alarms can only be SET or CLEARED from within the alarm
screen. From the main working screen, press
VIEW
to access the
Operator Alarm screen. The cursor is an arrow that points to the
alarm, which may be set or cleared and is always at the first
position when entering the alarm screen. It may be moved to any
position on the alarm screen by use of the
UP/DOWN
arrows.
When the cursor is pointing to an alarm, the numerical value
displayed will be the current position of the crane except when that alarm has previously been SET. In this
case, the SET value will be indicated and will alternate with the word, "SET." Alarms which are set but to
which the cursor is not pointing indicate the previously set value. Other alarms, which are NOT SET, are
indicated by the word, "OFF."
The functions of the push buttons when in the alarm screen are:
♦
♦
♦
♦
VIEW
VIEW
VIEW
VIEW
Used to access the alarm screen in order to view the currently set alarms.
♦
♦
♦
♦
SET
SET
SET
SET
Used to SET the alarm value. The alarm value is determined by the position of the crane at the
time the SET button is pressed.
♦
♦
♦
♦
CLEAR
CLEAR
CLEAR
CLEAR
Used to clear a previously SET alarm. Alarms can only be CLEARED when the cursor is
pointing to the item to be cleared. Use the UP/DOWN arrows to move the cursor to the desired alarm.
Press CLEAR to cancel that alarm.
♦
♦
♦
♦
UP/DOWN ARROWS
UP/DOWN ARROWS
UP/DOWN ARROWS
UP/DOWN ARROWS
Used to move the cursor up or down the screen to the alarm that is to be
viewed, SET or CLEARED.
♦
♦
♦
♦
SELECT
SELECT
SELECT
SELECT
Used to return to the normal operating screen.
WARNING
NOTE
INFORMATION
VIEW
SET
CLEAR
DOWN
UP
W