![GREER Company MG-534 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/greer-company/mg-534/mg-534_calibration_2264238014.webp)
Link-Belt MG-534 Calibration
10
W450160 10/07
Fault
Code
FKO
Power
Feed
ATB
Power
Feed
Display
Console
ADC 2
Internal
Fault
ADC 1
Internal
Fault
Action
025
X
X
X
Replace computer.
026
X
X
X
027
X
X
X
X
028
X
X
X
029
X
X
X
X
030
X
X
X
X
031
X
X
X
X
X
group “C” fault Codes
Group “C” fault codes represent faults detected for internal computer memories.
Fault
Code
Serial
EEPROM
Crane
Data
RAM
Duty Data Program
Action
000
No Fault Found
None
001
X
Replace system chip. Refer to “System
Chip (IC16)” on page 20 of the Trouble-
shooting manual (W450161)).
002
X
003
X
X
004
X
Replace computer.
005
X
X
Replace system chip. Refer to “System
Chip (IC16)” on page 20 of the Trouble-
shooting manual (W450161).
006
X
X
007
X
X
X
008
X
Reset crane data.
009
X
X
Replace system chip. Refer to “System
Chip (IC16)” on page 20 of the Trouble-
shooting manual (W450161).
010
X
X
011
X
X
X
012
X
X
Replace computer.
013
X
X
X
Replace system chip. Refer to “System
Chip (IC16)” on page 20 of the Trouble-
shooting manual (W450161).
014
X
X
X
015
X
X
X
X
016
X
Reselect crane setup/configuration.
Otherwise, replace computer if not
resolved.
017
X
X
Replace system chip. Refer to “System
Chip (IC16)” on page 20 of the Trouble-
shooting manual (W450161).
018
X
X
019
X
X
X
020
X
X
Replace computer.
021
X
X
X
Replace system chip. Refer to “System
Chip (IC16)” on page 20 of the Trouble-
shooting manual (W450161).
022
X
X
X
023
X
X
X
X
Содержание MG-534