background image

GREER COMPANY 

Crane Systems 

 

 

 

SPECIAL FUNCTIONS 

ALARM TEST 

 

WHILE NOT IN ANY PROCEDURE, PRESS AND HOLD ENTER 

TO SOUND 

THE HORN, LIGHT UP THE LED'S, DISPLAY "ALARM TEST," AND ACTIVATE 

ALL INSTALLED MOTION CUTS. 

RIGGING MODE 

 

PRESS AND HOLD THE 

DOWN ARROW; 

THEN PRESS 

ENTER 

TO 

ACTIVATE THE RIGGING MODE WHEN WORKING ON THE CRANE. 

NOTE: 

ALL ALARMS AND WARNINGS ARE DISABLED WHEN THE RIGGING 

MODE IS ACTIVE 

 

PRESS 

CANCEL ALARM 

TO EXIT THE RIGGING MODE. 

NOTE: 

THIS ACTION WILL RESTORE ALARMS AND MOTION CUT 

FEATURES (IF INSTALLED). 

CAL

I

BRAT

ION MODE 

 

TO ACCESS THE CALIBRATION MODE, PRESS THE 

UP AND DOWN 

ARROWS AT THE SAME TIME. 

NOTE: 

A PROMPT WILL REQUEST ENTRY OF A 

KEY CODE

. (SEE THE 

CALIBRATION MANUAL FOR THIS CODE.) IF CODE IS NOT ENTERED, 

"ACCESS DENIED" WILL APPEAR AND THE NORMAL SCREEN WILL 

RETURN. 

CONTRAST KEYS 

 

PRESS THE 

UP OR DOWN CONTRAST KEYS (

ON FAR RIGHT OF DISPLAY) 

TO MAKE READOUT LETTERS ON THE DISPLAY LIGHTER OR DARKER. 

Содержание Crane Systems BA 1510

Страница 1: ...GREER COMPANY Crane Systems BA 1510 ANGLE INDICATOR OPERATOR S MANUAL HYDRAULIC LATTICE CRANES...

Страница 2: ...ienced crane operator in safe crane setup and operation involving boom angles This manual provides the operator with instructions for using the BA 1510 System At no time may this System be used as a s...

Страница 3: ...ANUAL HYDRAULIC LATTICE CRANES BA 1510 ANGLE INDICATOR 5 SETTING AN ANGLE LIMIT LIMIT 5 REMOVING AN ANGLE LIMIT 5 THE ALARMS 6 PRE ALARMS 6 ALARMS 6 MOTION CUTS 7 SPECIAL FUNCTIONS 8 FACTORY RECOMMEND...

Страница 4: ...maximum limit Range 9 9 to 99 9 press to set cancel limits yellow and red warning lamps angle of crane boom press to lighten darken display The BA 1510 Angle Indicator meter BA 1510 Operator s Manual...

Страница 5: ...nd boom down movements are available as an additional option if desired Refer to MOTION CUTS page 7 SETTING AN ANGLE LIMIT Position the crane boom at the desired limit Refer to the illustration on the...

Страница 6: ...nds both the red and yellow lamps light up and a warning message appears Motion cuts if installed will activate OPTIONS WHEN AN ALARM ACTIVATES MOVE OUT OF THE ALARM CONDITION PRESS CANCEL ALARM TO SI...

Страница 7: ...ST UP BOOM DOWN AND TELESCOPE OUT BOOM ACTION DURING A TWO BLOCK CONDITION ACTIVATION OF THE MIN ANGLE ALARM HALTS BOOM DOWN UNLESS THE ALARM WAS PURCHASED AS AUDIOVISUAL ALARMS ONLY ACTIVATION OF THE...

Страница 8: ...ABLED WHEN THE RIGGING MODE IS ACTIVE PRESS CANCEL ALARM TO EXIT THE RIGGING MODE NOTE THIS ACTION WILL RESTORE ALARMS AND MOTION CUT FEATURES IF INSTALLED CALIBRATION MODE TO ACCESS THE CALIBRATION M...

Страница 9: ...LLED 2 IF USING AN ANTI TWO BLOCK SYSTEM TEST THE SYSTEM BY CAUTIOUSLY HOISTING THE HOOK S TO ACTUATE THE SWITCH AND ALARM 3 CHECK THE METER FOR ANY VISIBLE MOISTURE AND KEEP IT AS DRY AS POSSIBLE MON...

Страница 10: ...ALLY OR EVERY 1000 HOURS OF OPERATION 1 UNDO THE CABLE CONNECTORS IN THE SYSTEM INSPECT AND CLEAN THESE CONNECTORS GENEROUSLY REPACK EACH CONNECTOR WITH DOW CORNING 111 SILICON GREASE OR A COMPARABLE...

Страница 11: ......

Страница 12: ...12...

Отзывы: