English (original instructions)
EN
DE ES IT FR PT NL RU FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET
SPECiFiCATiONS
Voltage
60V DC
No load speed
5000±10% rpm
Guide bar length
16 in. (406 mm)
Chain stop
< 3s
Chain oil tank capacity
170 ml
Weight
(with 4Ah battery pack)
Max 4.3kg ( without guide
bar and saw chain )
Emission sound
pressure level LpA
81.5dB(A)
Uncertainty KpA
3.0dB(A)
Sound power level LwA
94.7dB(A)
Guaranteed sound
power level LwA(G)
97dB(A)
Vibration total value ah
2.5m/s
2
Uncertainty KwA
1.5m/s
2
REMARKS:
The declared vibration value has been measured with
a standard test method and may be used to compare
one tool with another.
The declared vibration value may be used in a
preliminary assessment of exposure.
wARNiNG
The actual vibration values during use of the tool can
be different from the above stated and depend on the
use of the tool; and the need to identify safety measures
to protect the operator are based on an estimation of
exposure in the actual conditions of use (taking account
all parts of the operating cycle such as the times when
the tool is switched off and when it is running idle in
addition to the trigger time).
CHAiN & BAR iNFORMATiON
2001807
Manufacture
Saw chain
Guide bar
Oregon
91PJ056X
160SDEA041
Oregon's chain must be fitted with Oregon's bar;
Trilink's chain must be fitted with Tri-link's bar.
DESCRiPTiON
1. Safety Lock
2. Trigger
3. Rear Handle
4. Front Handle
5. Quick View Oil Indicator
6. Oil Cap
7. Low Kickback Chain
8. Chain Brake
9. Bar
10. Sprocket cover tighten nuts
11. Chain Tensioner adjust knob
12. Wrench
13. Scabbard
14. Sprocket cover
15. Chain cover
16. Bolt for saw chain tension
17. Sprocket
18. Spike bumpers
19. Oil outlet
20. Bar groove
21. Chain drive links
22. Cutter
23. Felling direction
24. Danger zone
25. Escape route
26. Direction of fall
27. Notch
28. Felling back cut
29. Hinge
30. Limb cut
31. Keep work off ground leave support limbs until log is
cut
32. Log supported along the entire length
33. Cut from top (over buck) avoid cutting earth
34. Log supported
35. Under buck
36. Over buck
FPO