![Greenwood Unity CV2GIP Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/greenwood/unity-cv2gip/unity-cv2gip_installation-instructions-manual_2263328012.webp)
12
Insert mains cable (A) and clamp using cable clamp provided (B).
Push the wires into the
terminal block (C) as per the
wiring diagram (see section
2.7). Tighten the terminal
block screws and ensure a
good connection.
Push circular low voltage
cable through cable entry point (D) and then secure cable using the cable
clamp (E).
Push the wires into the terminal block (F) as per the wiring diagram (see
section 2.7). Tighten the terminal block screws and ensure a good
connection.
Before fitting the SELV Box
Top remove suitable cable
knock outs that best suit
the entry position of both
the mains and low voltage
cables, ensure that they
are dressed and that all
sharp edges are removed to ensure cable insulation is not damaged.
Fit SELV Cover to SELV
Back Plate and Power
Supply and secure using
the 4 screws provided.
Insert low voltage cable
through the Unity fan’s
cable entry point and then secure cable using the cable clamp.
Push the wires into the fan’s terminal block as per the wiring diagram
(see section 2.7). Tighten the terminal block screws and ensure a good
connection.
2.8.4
2.8.5
2.8.6
2.8.7
2.8.8
2.8.9
2.8.10
2.8.11
From
Mains
Supply
A
B
C
F
D
E
To CV2SVGIP
Fan Terminal
Cable entry knock outs
SELV Cover
SELV Back Plate