11
Wiring Diagrams
2.7
Fan Specifications
230V Model:
IPX5 Wall, IPX4 Ceiling 220-240V ~ 50Hz / 1Ph
5 Watts max.
SELV Model:
IPX5 Wall, IPX4 Ceiling 24DC: between controller
and fan 220-240V ~ 50Hz / 1Ph 5 Watts max.
Cable Sizes:
Mains: Fixed flat wiring 2 core 1mm
2
, 3 core
1/1.5mm
2
SELV Output: Circular wiring 3 core 0.75mm
2
CV2GIP
CV2SVGIP
2.6.9
SELV Box Installation
Install SELV Back Plate and Power Supply (see images on page 12),
using the two fixing holes, in a suitable location outside of the room
where the Unity SELV fan (CV2SVGIP) is installed. The location should be
as such that air can circulate around the Power Supply unit and it should
never be covered.
The distance between the fan and the SELV Back Plate and Power Supply
should be kept to a minimum and ideally not be greater than 3.0m.
Strip cable to correct length (as shown in section 2.6.8) for CV2SVGIP and
SELV Back Plate.
2.8
2.8.1
2.8.2
2.8.3