Greenwood Unity CV2GIP Скачать руководство пользователя страница 1

Unity CV2GIP / CV2SVGIP

Decentralised Mechanical Extract Ventilation (dMEV)

Installation Instructions

Commissioning Data: 

To be completed by the 

Commissioning Engineer. 

Refer to User / Homeowner Guide 

also supplied.

Notice: 

For Wall Mounting: 

To ensure IPX5 install fan with 

orientation       arrows facing upwards. 

(See section 2.3, figure 5)

Содержание Unity CV2GIP

Страница 1: ...ation dMEV Installation Instructions Commissioning Data To be completed by the Commissioning Engineer Refer to User Homeowner Guide also supplied Notice For Wall Mounting To ensure IPX5 install fan wi...

Страница 2: ...disassemble the unit disconnect from mains supply and use a screwdriver to segregate the electronic components and motor from the plastic housing Dispose items in accordance with WEEE WEEE Statement...

Страница 3: ...provide a comfortable indoor environment Either a switch live light switch or an alternative boost switch not supplied should be wired to provide this operation see section 2 6 Electrical This product...

Страница 4: ...ithout supervision Where an open flued oil or gas fuelled appliance is installed precautions must be taken to avoid a back flow of gases into the room When installing wall mounted fans ensure that the...

Страница 5: ...ons in respect of this Installation of the unit should be in accordance with the current editions of Building Regulations and BS7671 IEE Wiring Regulations Electrical installation must only be carried...

Страница 6: ...xing screws until they lock to maintain IPX5 and avoid possible hazard To attach the outer front cover rotate to the right utilising the guidance rail until firmly secured by the retaining clips Wall...

Страница 7: ...tain IPX4 and avoid possible hazard To attach the outer front cover rotate to the right utilising the guidance rail until firmly secured by the retaining clips 7 6 Carefully close the electronics cove...

Страница 8: ...Where access to ducts will not be possible after construction is complete i e within floor and wall voids consideration should be given to permanent connection and sealing with an appropriate non har...

Страница 9: ...separation of 3mm must be used to provide isolation for the unit When supplied from a 6 amp lighting circuit no local fuse is required If electricity is not supplied via the lighting circuit a localis...

Страница 10: ...able using the cable clamp B Push the wires into the terminal block C as per wiring diagram see section 2 7 Tighten screws of the terminal connection Note A facility to park the earth cable has been p...

Страница 11: ...lation Install SELV Back Plate and Power Supply see images on page 12 using the two fixing holes in a suitable location outside of the room where the Unity SELV fan CV2SVGIP is installed The location...

Страница 12: ...e knock outs that best suit the entry position of both the mains and low voltage cables ensure that they are dressed and that all sharp edges are removed to ensure cable insulation is not damaged Fit...

Страница 13: ...e Airflow Commissioning On Site Commissioning Set Up This section covers set up configuration of the unit for installation and altering pre set factory settings Removal of the Front Cover and Control...

Страница 14: ...umidiSMART press button to turn on light will go solid For TimerSMART press button to turn on light will go solid Step 5 Step 4 Bathroom 8 l s Kitchen 13 l s Bathroom 5 l s Kitchen 8 l s Note Selectio...

Страница 15: ...ious commissioning should be recalled these can now be re adjusted Note To master reset press and hold buttons simultaneously for approximately 10 seconds until all lights flash to indicate the fan ha...

Страница 16: ...ch are available on request See website for warranty period details Zehnder Group UK Ltd reserves the right to change specifications and prices without prior notice Copyright Zehnder Group UK Ltd 2017...