background image

 

 

Product data sheet for household cooker hoods accordingly 

to regulation (EU). No. 65/2014 and 66/2014 

 

 

 

Symbol 

Value 

Unit 

Model identification 

EMF 990 

 

 

Annual Energy Consumption 

AEC

hood

 

90,2 

kWh/a 

Time increase factor 

1,4 

 

Fluid Dynamic Efficiency 

FDE

hood 

17,7 

 

Energy Efficiency Index 

EEI

hood 

78,9 

 

Measured airflow rate at the best 
efficiency 

Q

BEP 

375,0 

m3/h 

Measured air pressure at best 
efficiency point 

P

BEP 

302 

Pa 

Maximum airflow 

Q

max 

636,5 

m3/h 

Measured electric power input at best 
efficiency point 

W

BEP 

177,2 

Nominal power of the lighting system 

W

3,0 

Average illumination of the lighting 
system on the cooking surface 

E

middle 

302 

lux 

Measured power consumption on 
standby mode 

P

0,45 

Measured power consumption on off 
mode 

P

-- 

Sound power level 

L

WA 

71 

dB 

 

Содержание EMF 990

Страница 1: ...Instruction Manual EMF 990...

Страница 2: ...CONTENT 1 Warning 2 Function and Feature 3 Installation 4 Maintenance 5 Exchange the lamp 6 Energy data sheet...

Страница 3: ...h your cooker hood please call the service department appointed by agent for servicing Please keep the room draughty when your cooker hood and gas hob are working Do not exhaust the gas from cooker ho...

Страница 4: ...ped with a large power low noise electric motor and centrifugal leaf it produces strong suction low noise non stick grease filter and easy to clean With the isolated low voltage circuit board control...

Страница 5: ...l 1 170mm round hole in the ceiling According to the hanging board drill 9 holes in the ceiling 9pcs of ST6 40mm big flat screws will be used to fix the hanging board on the wood ceiling or drill 6 ho...

Страница 6: ...ect wire box take apart the lamp s wire from the box then take out the small round body See pic 4 5 6 Take off the small round body you should be careful to install the glass See pic 6 7 After install...

Страница 7: ...lap length of angle iron not less 100MM See pic 10 10 Use 6pcs of M4 10mm big flat screws to fix the angle iron on the hood and install the extensible pipe See pic 11 12 11 Use the fixation board to p...

Страница 8: ...put the extensible pipe on the ceiling after that use 6pcs of M4 10mm big flat screws and M4 nut with gasket will be used to connect the angle iron to the hanging board 14 See pic 16 Drag the inner c...

Страница 9: ...c 17 Please strictly follow the guidelines below 1 Put the mesh into 40 50 clean water pour on detergent and soak for 2 3 mins Wear gloves and clean with a soft brush Please do not apply too much pres...

Страница 10: ...grease filter be careful to take off the grease filter screws in the anticlockwise by hand drag down and pick the grease filter out See pic 19 See pic 20 21 use screw driver to take off the shelter bo...

Страница 11: ...ood 78 9 Measured airflow rate at the best efficiency QBEP 375 0 m3 h Measured air pressure at best efficiency point PBEP 302 Pa Maximum airflow Qmax 636 5 m3 h Measured electric power input at best e...

Отзывы: