Gator
®
Insulated Battery-Powered In-Line Crimper
Greenlee Tools, Inc.
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
17
LED Indicator (red)
This tool is equipped with a special circuit board
incorporating several important features to inform
the user about the current status of the unit. The LED
signals in the following cases:
What happens
Signal
What it means
What to
do
Tool will
not
start,
and constant light for
20 seconds when trigger
is released
Battery
charge low
Change
or charge
battery
Tool will stop, and
constant light for
20 seconds after trigger
is released
Tool will stop, and
flashing light for
20 seconds when
trigger is released
Motor current
exceeds 20 A
during cycle
Let tool
cool
Circuit has
become too hot
Flashing light for 20
seconds at end of cycle
and
audible
warning
Indicates 4,750
cycles exceeded
or 21 months
exceeded
Send tool
in for
service
Error
Code
Meaning
Action
1
Overcurrent fuse
Seek Service
2
Overcurrent comparator
Seek Service
3
Overheated circuit board
Cool Tool
4
Overheated battery
Cool Battery
5
Battery empty; operation
stops
Charge Battery
6
Faulty crimp; complete
cycle
Seek Service
7
Faulty crimp; incomplete
cycle
Seek Service
8
Low battery
Charge Battery
9
Battery empty
Charge Battery
10
Real-time clock battery
low
Seek Service
11
Tool deactivated
Seek Service
12
Service necessary
Seek Service
13
Real-time clock not
found
1. Re-insert Battery
2. Seek Service
14
Bluetooth
®
unit not found
1. Re-insert Battery
2. Seek Service
15
[Not Used]
16
Pressure sensor not
found
Seek Service
17
Burst pressure exceeded
Seek Service
18
Battery temperature too
low
Warm Battery
19
Blinking Screen 4,750
cycles exceeded
Seek Service
If certain problems arise with the tool, an error code
appears on the LCD screen (see pg. 14).
Troubleshooting
(cont'd)
Note: The tool will indicate when re-certification is near.
Starting at 4,750 cycles or 21 months (whichever occurs
first), the red LED and work LED will flash, an audible
warning will sound, and the LED will display SERVICE
NECESSARY for 20 seconds after every cyce. After
5,000 cycles or 2 years, the tool will not operate unless
the battery is removed and reinstalled. Only one cycle is
possible each time the battery is reinstalled.