Greenlee Tools, Inc.
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
10
EK1230LX and EK1230CLX Crimping Tools
Maintenance
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from flying
debris or hydraulic oil.
Skin injection hazard:
Do not use hands to check for oil
leaks. Oil under pressure easily punc-
tures skin. If injured, seek medical
attention immediately to remove oil.
Failure to observe this warning could
result in serious injury, gangrene, or
death.
Do not use solvents or flammable
liquids to clean the tool body.
Solvents or flammable liquids could
ignite and cause serious injury or
property damage.
Pinch points:
• Remove battery before changing
dies, adapters, or jaws.
• Keep hands away from the crimp-
ing tool head when crimping.
Failure to observe these warnings
could result in severe injury or death.
Relief valve adjustments must be done by an
authorized service center.
Daily
Before use:
1. Inspect the tool for wear or damage, such as cracks,
gouges, or chips.
2. Inspect the tool for damage or leaks.
3. Inspect the rotation of the head assembly. Fully
retract the ram. The head should rotate no more
than 360°. If damage is detected, contact Greenlee
customer service at 800-435-0786 for warranty
service or repair.
After use:
1. Use a damp cloth and mild detergent to clean the
housing. Allow the housing to dry.
2. Fully retract the ram. Place the tool in the carrying
case and store in a cool, dry place.
3. If necessary, recharge the batteries. Refer to the
instructions supplied with the battery charger.
Monthly
Thoroughly clean all surfaces.
Annually or After 10,000 Crimps
Contact Greenlee customer service at 800-435-0786 for
warranty service or repair, and hydraulic oil replacement.