CMI-100
9
Using the Features
•
RANGE
Press once to enter the manual ranging mode. The AUTO icon will disappear
from the display. Press repeatedly to step through the ranges. Press and hold to return to
the automatic ranging mode.
Note: The autoranging feature is not available in the MAX/MIN and
∆
modes.
•
MAX/MIN (PEAK)
Holds the minimum or maximum value on the display. Since this feature
only operates with manual ranging, press the
RANGE
button first to select the
appropriate range, as described above. Press once to hold the minimum value; press again
to hold the maximum value (or peak value, if measuring an AC signal). Press again to exit
this mode.
•
∆
ZERO
Finds the difference between two measurements. While taking a measurement,
press
∆
to set the display to zero. The
∆
icon will appear on the display. Take the second
measurement. The value on the display will be the difference between the two measure-
ments. Press and hold to exit this mode.
•
HOLD
Press momentarily to hold the present value on the display. Press again to exit
this mode.