CMGL-10
13
Value
Range
Accuracy at
Accuracy at
Input
50 Hz - 60 Hz
40 Hz - 1 kHz
Impedance
39.99 mA
±
(1.0% + 0.03 mA)
±
(2.0% + 0.05 mA)
N/A
399.9 mA
±
(1.0% + 0.3 mA)
±
(2.0% + 0.5 mA)
N/A
Current
3.999 A
±
(1.0% + 0.003 A)
±
(2.0% + 0.005 A)
N/A
39.99 A
±
(1.0% + 0.03 A)
±
(2.0% + 0.05 A)
N/A
60 A (0-50 A)
±
(1.5% + 0.3 A)
±
(3.0% + 0.5 A)
N/A
60 A (50-60 A)
±
(3% + 1.0 A)
±
(3.5% + 0.5 A)
N/A
Voltage
399.9 V
±
(1.5% + 0.2 V)
±
(2.0% + 0.4 V)
10 M
Ω
Accuracy
Accuracy is specified as follows:
±
(a percentage of the reading + a fixed amount)
at 18
°
C to 28
°
C (64
°
F to 82
°
F), 0% to 85% relative humidity.
Value
Range
Accuracy
Open Circuit
Voltage
Resistance
399.9
±
(1.0% + 0.2
Ω
)
0.4 V
Continuity
Threshold: Tone indicates circuit resistance is less than approximately 40
Ω
.
Open Circuit Voltage:
≤
0.4 V