Important Safety Information

Electric shock hazard:
Contact with live circuits could result in severe injury or death.

Electric shock and fire hazard: 

Do not expose this unit to rain or moisture.

• 

Do not use the unit if it is wet or damaged.

• 

Use test leads or accessories that are appropriate for the application. Refer to the category and 

• 

voltage rating of the test lead or accessory.
Inspect the test leads or accessory before use. They must be clean and dry, and the insulation 

• 

must be in good condition.
Use this unit for the manufacturer’s intended purpose only, as described in this manual. Any other 

• 

use can impair the protection provided by the unit.

Failure to observe these warnings could result in severe injury or death.

Electric shock hazard:

Verify that the unit is not in hold mode before making a measurement. The unit may be in hold 

• 

mode when turned on. Hold mode is not affected by turning the unit off or by changing the position 
of the selector.
Do not apply more than the rated voltage between any two input terminals, or between any input 

• 

terminal and earth ground.
Do not contact the test lead tips or any uninsulated portion of the accessory.

• 
Failure to observe these warnings could result in severe injury or death.

Содержание CM-600

Страница 1: ...ANUAL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool CM 600 CM 650 Clamp on Meters 99945550 2008 Greenlee Textron Inc IM 1520...

Страница 2: ...tion provided Purpose of This Manual This instruction manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee CM 600 and CM 650 Clamp on Met...

Страница 3: ...reventing or avoiding the hazard Immediate hazards which if not avoided WILL result in severe injury or death Hazards which if not avoided COULD result in severe injury or death Hazards or unsafe prac...

Страница 4: ...it for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit Failure to observe these warnings could result in severe injury...

Страница 5: ...able or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the measurement function while the test leads are connected to...

Страница 6: ...l 7 V terminal 8 Battery Cover 9 Battery Cover Screw Symbols on the Unit Warning Read the instruction manual Double insulation Battery 5 6 4 2 1 7 3 9 8 Front Back Display Icons 10 Hold function is en...

Страница 7: ...ing method uses internal circuitry to read the true RMS value This method is accurate within the specified crest factor limitations whether the input signal is a pure sine wave a square wave sawtooth...

Страница 8: ...specific measurement instructions 3 Test the unit on a known functioning circuit or component If the unit does not function as expected on a known functioning circuit replace the battery If the unit s...

Страница 9: ...y Close the jaw completely Center the wire in the jaw for highest accuracy Clamp Around Line Splitter Notes The Greenlee 93 30 Line Splitter is divided One section renders amps the other renders amps...

Страница 10: ...0 Hz N A AC Current 600 A range 0 to 400 A 1 5 5 A 50 60 Hz N A 400 to 600 A 2 5 5 A 50 60 Hz Resistance 0 to 2000 1 5 2 N A N A Maximum open circuit voltage 1 V Continuity Threshold Tone sounds if th...

Страница 11: ...humidity Remove battery Indoor use only Altitude 2000 m 6500 maximum Pollution Degree 2 Battery 9 Volt battery NEDA 1604 JIS 006P or IEC 6LF22 Battery Replacement Electric shock hazard Before opening...

Страница 12: ...Customer Service at 800 435 0786 and request a Return Authorization For items not covered under warranty such as items dropped abused etc a repair cost quote is available upon request Note Prior to r...