Description

The Greenlee CM-600 and CM-650 Clamp-on Meters are versatile clamp-on meters intended to 
measure AC current, AC voltage, resistance and to verify continuity. These units also have data hold 
capability. In addition, the CM-650 is a true RMS reading meter.

Safety

Safety is essential in the use and maintenance of Greenlee tools and equipment. This instruction 
manual and any markings on the tool provide information for avoiding hazards and unsafe practices 
related to the use of this tool. Observe all of the safety information provided.

Purpose of This Manual

This instruction manual is intended to familiarize all personnel with the safe operation and maintenance 
procedures for the Greenlee CM-600 and CM-650 Clamp-on Meters.
Keep this manual available to all personnel.
Replacement manuals are available upon request at no charge at www.greenlee.com.

Do not discard this product or throw away!  

For recycling information, go to www.greenlee.com.

All specifications are nominal and may change as design improvements occur. Greenlee Textron Inc. shall not be liable 

for damages resulting from misapplication or misuse of its products.
® Registered:  The color green for electrical test instruments is a registered trademark of Greenlee Textron Inc.

KEEP THIS MANUAL

Содержание CM-600

Страница 1: ...ANUAL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool CM 600 CM 650 Clamp on Meters 99945550 2008 Greenlee Textron Inc IM 1520...

Страница 2: ...tion provided Purpose of This Manual This instruction manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee CM 600 and CM 650 Clamp on Met...

Страница 3: ...reventing or avoiding the hazard Immediate hazards which if not avoided WILL result in severe injury or death Hazards which if not avoided COULD result in severe injury or death Hazards or unsafe prac...

Страница 4: ...it for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit Failure to observe these warnings could result in severe injury...

Страница 5: ...able or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the measurement function while the test leads are connected to...

Страница 6: ...l 7 V terminal 8 Battery Cover 9 Battery Cover Screw Symbols on the Unit Warning Read the instruction manual Double insulation Battery 5 6 4 2 1 7 3 9 8 Front Back Display Icons 10 Hold function is en...

Страница 7: ...ing method uses internal circuitry to read the true RMS value This method is accurate within the specified crest factor limitations whether the input signal is a pure sine wave a square wave sawtooth...

Страница 8: ...specific measurement instructions 3 Test the unit on a known functioning circuit or component If the unit does not function as expected on a known functioning circuit replace the battery If the unit s...

Страница 9: ...y Close the jaw completely Center the wire in the jaw for highest accuracy Clamp Around Line Splitter Notes The Greenlee 93 30 Line Splitter is divided One section renders amps the other renders amps...

Страница 10: ...0 Hz N A AC Current 600 A range 0 to 400 A 1 5 5 A 50 60 Hz N A 400 to 600 A 2 5 5 A 50 60 Hz Resistance 0 to 2000 1 5 2 N A N A Maximum open circuit voltage 1 V Continuity Threshold Tone sounds if th...

Страница 11: ...humidity Remove battery Indoor use only Altitude 2000 m 6500 maximum Pollution Degree 2 Battery 9 Volt battery NEDA 1604 JIS 006P or IEC 6LF22 Battery Replacement Electric shock hazard Before opening...

Страница 12: ...Customer Service at 800 435 0786 and request a Return Authorization For items not covered under warranty such as items dropped abused etc a repair cost quote is available upon request Note Prior to r...

Отзывы: