Accuracy 

(cont’d)

Resistance

Range

Accuracy

199.99 mΩ

± (1% + 0.05 mΩ)

1.9999 Ω

± (1% + 0.5 mΩ)

19.999 Ω

± (1% + 5 mΩ)

199.99 Ω

± (1% + 50 mΩ)

1999.9 Ω

± (1% + 0.5 mΩ)

Temperature: 

±1.5 °C

Specifications

Display:  LCD, 4-1/2 digits 20,000 counts
Operating Conditions:  32 °F to 104 °F (0 °C to 40 °C), 

relative humidity < 75%

Storage Conditions:  -4 °F to 140 °F (-20 °C to 60 °C), 

relative humidity < 85%

Battery:  Six 1.5 V batteries (AA, NEDA 15A, IEC LR6)
Dimensions:  198 mm x 98 mm x 56 mm  

(7.8" x 3.9" x 2.2")

Current Consumption:

Backlight OFF and no cable is being 

measured:  Approximately 5 mA

When a cable is being measured:   

Approximately 100 mA

APO Timing: Idle for 10 minutes
Low Battery Indicator:  Approximately 7.2 V

Statement of Conformity

Greenlee Textron Inc. is certified in accordance with 

ISO 9001 (2000) for our Quality Management Systems.
The instrument enclosed has been checked and/or cali-

brated using equipment that is traceable to the National 

Institute for Standards and Technology (NIST).

Maintenance

Electric shock hazard:
Before opening the case, remove the test leads from the 

circuit and shut off the unit.
Failure to observe this warning could result in severe 

injury or death.

Replacing the Batteries

1.  Turn the unit OFF. Remove the Kelvin clip leads from 

the meter.

2.  Remove one screw from the battery access door and 

remove it.

3.  Replace the batteries, making sure to observe the 

polarity.

4.  Replace cover and continue with normal operation.

Cleaning and Storage

Periodically wipe the case with a damp cloth and mild 

detergent; do not use abrasives or solvents.
If the meter will not be used for periods longer than 

60 days, remove the batteries and store them separately.

www.

.com

[email protected]

1.800.561.8187

Содержание CLM-1000

Страница 1: ...toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle Anweisungen u...

Страница 2: ...150 185 240 mm2 61 strands 300 400 500 Other capabilities include Automatic temperature compensation Hold Mode to capture the present LCD value Programmable Auto Power Off Automatic ranging Backlight...

Страница 3: ...connect this unit to live voltage Do not expose this unit to rain or moisture Do not use the unit if it is wet or damaged Using this unit near equipment that generates electromagnetic interference ca...

Страница 4: ...struction manual Warning Risk of electric shock Double insulation Display Icons 1 Low battery indicator 2 User selected switch position 3 Ambient temperature indication 4 Resistance Mode 5 Copper 6 Al...

Страница 5: ...e press the HOLD FT M or Cu Al button dH is no longer present on the LCD Auto Power Off APO When enabled the meter will automatically turn OFF after 10 minutes of inactiv ity Inactivity is defined as...

Страница 6: ...e odd cable sizes AWG 5 7 9 11 AWG etc CLM 1000 When measuring odd numbered cable sizes set the rotary switch to the next smaller size and multiply the reading by 1 261 For example to measure a 9 AWG...

Страница 7: ...Typical Measurements Typical Configuration Calibration Note Make sure that the clips are as close together as possible in order to improve calibration accuracy Calibration Bar www com information itm...

Страница 8: ...0 01 kft 100 00 kft 1 5 0 33 kft Length in meters Gauges CLM 1000 Diameter mm2 CLM 1000E Accuracy Range Length Range Accuracy 18 AWG 2 AWG 0 75 35 1000 0 m 5 m 152 4 m 1 0 1 6 m 152 5 m 304 8 m 1 0 2...

Страница 9: ...h ISO 9001 2000 for our Quality Management Systems The instrument enclosed has been checked and or cali brated using equipment that is traceable to the National Institute for Standards and Technology...

Отзывы: