CLM-1000 • CLM-1000E

Using the Features

• 

:

  Press momentarily to turn the backlight ON. Once 

lit, press button again to turn the backlight OFF.  The 

backlight automatically turns OFF after approximately 

30 seconds to extend battery life.

• 

FT/M:

  Press momentarily to select length measurement 

units. On the LCD, “ft” indicates feet and “m” indicates 

meters.

• 

CAL:

  The meter must be calibrated each time it is 

turned ON. Refer to “Operation” for a complete descrip-

tion of the calibration process.

• 

Esc:

  Press to escape from programming process.

• 

MEM:

  Button is used for the user-selected program-

ming function. Refer to “Operation” for a complete 

description of the programming process.

• 

Cu/Al:

  Press momentarily to select cable material. 

On the LCD, “Cu” indicates copper and “Al” indicates 

aluminum.

• 

HOLD:

  Press momentarily to enter data hold mode. 

When button is pressed, “dH” is present on the LCD and 

the current value is captured. To exit this mode, press 

the 

HOLD

FT/M

 or 

Cu/Al

 button. “dH” is no longer 

present on the LCD.

• 

Auto Power Off (APO):

  When enabled, the meter will 

automatically turn OFF after 10 minutes of inactiv-

ity. Inactivity is defined as no button press or rotary 

switch movement. The buzzer sounds three times 

approximately 30 seconds before the meter turns OFF 

as a warning. To disable APO, press and hold the 

HOLD

 

button while turning the meter ON.

• 

qp

:

  Used during the user-selected programming 

process. Refer to “Operation” for a complete description 

of the programming process.

Programmable Switch Positions User’s Table

Use this table to keep track of the cable size that has been programmed into a switch position.  

Make annotations with something erasable because switch positions can be reprogrammed.

Switch 

Position

Gauge

Material Type

Size

Type 

(circle)

1

mm

2

 AWG kcmil aught

Cu 

or

 Al

2

mm

2

 AWG kcmil aught

Cu 

or

 Al

3

mm

2

 AWG kcmil aught

Cu 

or

 Al

4

mm

2

 AWG kcmil aught

Cu 

or

 Al

5

mm

2

 AWG kcmil aught

Cu 

or

 Al

6

mm

2

 AWG kcmil aught

Cu 

or

 Al

7

mm

2

 AWG kcmil aught

Cu 

or

 Al

8

mm

2

 AWG kcmil aught

Cu 

or

 Al

www.

.com

[email protected]

1.800.561.8187

Содержание CLM-1000

Страница 1: ...toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle Anweisungen u...

Страница 2: ...150 185 240 mm2 61 strands 300 400 500 Other capabilities include Automatic temperature compensation Hold Mode to capture the present LCD value Programmable Auto Power Off Automatic ranging Backlight...

Страница 3: ...connect this unit to live voltage Do not expose this unit to rain or moisture Do not use the unit if it is wet or damaged Using this unit near equipment that generates electromagnetic interference ca...

Страница 4: ...struction manual Warning Risk of electric shock Double insulation Display Icons 1 Low battery indicator 2 User selected switch position 3 Ambient temperature indication 4 Resistance Mode 5 Copper 6 Al...

Страница 5: ...e press the HOLD FT M or Cu Al button dH is no longer present on the LCD Auto Power Off APO When enabled the meter will automatically turn OFF after 10 minutes of inactiv ity Inactivity is defined as...

Страница 6: ...e odd cable sizes AWG 5 7 9 11 AWG etc CLM 1000 When measuring odd numbered cable sizes set the rotary switch to the next smaller size and multiply the reading by 1 261 For example to measure a 9 AWG...

Страница 7: ...Typical Measurements Typical Configuration Calibration Note Make sure that the clips are as close together as possible in order to improve calibration accuracy Calibration Bar www com information itm...

Страница 8: ...0 01 kft 100 00 kft 1 5 0 33 kft Length in meters Gauges CLM 1000 Diameter mm2 CLM 1000E Accuracy Range Length Range Accuracy 18 AWG 2 AWG 0 75 35 1000 0 m 5 m 152 4 m 1 0 1 6 m 152 5 m 304 8 m 1 0 2...

Страница 9: ...h ISO 9001 2000 for our Quality Management Systems The instrument enclosed has been checked and or cali brated using equipment that is traceable to the National Institute for Standards and Technology...

Отзывы: