960 PS Series Hydraulic Power Pumps
Setup
Hydraulic Connection
1.
Clean all couplers, threaded fittings, and ports.
2.
Remove any dust plugs from couplers.
3.
Hand-tighten all couplers firmly. Do not use tools.
4.
Install hydraulic oil. Refer to the “Specifications”
section of this manual to determine the correct type
of hydraulic oil.
Electric shock hazard:
• Do not modify the plug provided
with the tool.
• Connect this tool to a grounded
receptacle on a 15-amp GFCI-
protected circuit.
Failure to observe these warnings
can result in severe injury or death.
This tool must be grounded. In the event of a malfunc-
tion or breakdown, an electrical ground provides a path
of least resistance for the electric current. This path of
least resistance is intended to reduce the risk of electric
shock.
This tool’s electric cord has a grounding conductor and a
grounding plug as shown. Do not modify the plug.
Connect the plug to a corresponding 15-amp GFCI
protected receptacle that is properly installed and
grounded in accordance with all national and local codes
and ordinances.
Do not use an adapter.
Electrical Connection
Extension cord specifications:
Diameter ....................................... 2.5 mm
2
(12 AWG)
Length ..................................................... 30 m (100 ft)
Use only three-wire extension cords. Use of an
inadequate extension cord will cause the motor to stall.
Receptacle
Plug