93-606
13
Accuracy
See the Specifications section for operating conditions and temperature coefficient.
Accuracy is specified as follows:
±
(a percentage of the r a fixed amount)
at 23
°
C
±
5
°
C (73.4
°
F
±
9
°
F), 0% to 80% relative humidity.
AC Voltage
Range
Accuracy
Frequency Range
Input Impedance
199.9 mV
±
(1.2% + 0.4 mV)
1.999 V
±
(1.2% + 0.004 V)
19.99 V
±
(1.2% + 0.04 V)
40 Hz to 500 Hz
10 M
Ω
199.9 V
±
(1.2% + 0.4 V)
600 V
±
(1.5% + 4 V)
DC Current
Range
Accuracy
Burden Voltage
199.9
µ
A
±
(1.2% + 0.1
µ
A)
1.999 mA
±
(1.2% + 0.001 mA)
< 0.7 V
19.99 mA
±
(1.2% + 0.01 mA)
199.9 mA
±
(1.2% + 0.1 mA)
10.00 A*
±
(2.0% + 0.03 A)
< 0.3 V
* Duty Cycle: 60 seconds on, 5 minutes off
AC Current
Range
Accuracy
Frequency Range
Burden Voltage
199.9
µ
A
±
(1.5% + 0.4
µ
A)
1.999 mA
±
(1.5% + 0.004 mA)
< 0.7 V
19.99 mA
±
(1.5% + 0.04 mA)
40 Hz to 500 Hz
199.9 mA
±
(1.5% + 0.4 mA)
10.00 A*
±
(2.5% + .04 A)
< 0.3 V
* Duty Cycle: 60 seconds on, 5 minutes off
DC Voltage
Range
Accuracy
Input Impedance
199.9 mV
±
(0.5% + 0.1 mV)
1.999 V
±
(0.8% + 0.001 V)
19.99 V
±
(0.8% + 0.01 V)
10 M
Ω
199.9 V
±
(0.8% + 0.1 V)
600 V
±
(0.8% + 1 V)
Содержание 93-606
Страница 10: ...10 Typical Measurements Current Measurement Voltage Measurement...
Страница 11: ...93 606 11 Typical Measurements Resistance Measurement Continuity Check...
Страница 12: ...12 Diode Measurement Typical Measurements Forward Bias Reverse Bias...
Страница 25: ...93 606 25 Mediciones m s comunes Medici n de corriente Medici n de tensi n...
Страница 26: ...26 Mediciones m s comunes Medici n de resistencia Verificaci n de continuidad...
Страница 40: ...40 Mesures types Mesure du courant Mesure de la tension...
Страница 41: ...93 606 41 Mesures types Mesure de la r sistance V rification de la continuit...
Страница 42: ...42 Mesures types Mesure des diodes Forward Bias Reverse Bias Polarit inverse Polarit directe...
Страница 47: ...93 606 47 Greenlee Textron Subsidiary of Textron Inc 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070...