Recording Data
(cont’d)
Viewing Stored Recordings
1. Set the rotary switch to
MR
.
2. The instrument displays the last recording stored in the instrument. The secondary (top)
display indicates the memory location; while the main display indicates the measured value.
To see the other measurements, press the
p
button. The record number is decremented
and the corresponding measurement is displayed.
3. To scroll rapidly through the recorded measurements, keep the
p
button pressed.
4. To select a specific recording, use the
u
button to change the recording number.
5. Once you select the recording number, you can see all information associated with the
measurement. Press the
MEM
button for >2 seconds, then use the
p
button to scroll the
information.
6. When finished viewing recordings, press
MEM
for >2 seconds.
100V
V
k
Ω
MR
OFF
Ω
250V
500V
1000V
50V
M
Ω
M
MEM