Installation, Operation and Maintenance Manual

Please read and save these instructions for future reference. Read carefully before attempting to assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety 
information. Failure to comply with instructions could result in personal injury and/or property damage!

1

VGN Technology

®

®

Document 481885 

Vektor 

®

 Laboratory Exhaust  

with Variable Geometry Nozzle (VGN) Technology  

Electrical Controls Information

DANGER

Always disconnect power before working on or near a 
unit. Lock and tag the disconnect switch or breaker to 
prevent accidental power up.

CAUTION

When servicing the unit, variable frequency drives 
(VFD) may be hot enough to cause pain or injury. 
Allow motor to cool before servicing.

General Safety Information

Only qualified personnel should install this unit. 
Personnel should have a clear understanding of these 
instructions and should be aware of general safety 
precautions. Improper installation can result in electric 
shock, possible injury due to coming in contact with 
moving parts, as well as other potential hazards. Other 
considerations may be required if high winds or seismic 
activity are present. If more information is needed, 
contact a licensed professional engineer before moving 
forward.

1.  Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC), the National Fire 
Protection Agency (NFPA), where applicable. Follow 
the Canadian Electrical Code (CEC) in Canada.

2.  Do not allow the power cable to kink or come in 

contact with oil, grease, hot surfaces, or chemicals. 
Replace cord immediately if damaged.

3.  Verify the power source is compatible with the 

equipment.

Table of Contents

Receiving, Handling and Storage  . . . . . . . . . . . . . . . . . 2
Variable Geometry Nozzle (VGN) Control System 
   Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Quick Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . 4
VGN System Function Overview  
  Mounting of VGN Controller . . . . . . . . . . . . . . . . . . . . 5
  Nozzle to Pressure Transducer Box . . . . . . . . . . . . . . 5
  VGN Controller to Pressure Transducer Box  . . . . . . . 5
VGN Controller to VFD and BMS Hardwiring
   Fan Run Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
 BMS 

Communication 

. . . . . . . . . . . . . . . . . . . . . . . . . 6

  

 

Nozzle 

Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

  

 

Fan 

Flow 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    Outlet Velocity: On the Fly Unoccupied Adjustment  7
VGN Controller Incoming Power Wiring Instructions. . . 7
BMS Communication Programming
 Fan 

Run 

Signal 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

 Nozzle 

Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

 Fan 

Flow 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

 Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
   Outlet Velocity: On the Fly Unoccupied Adjustment 

   and Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9

Wiring Diagram - Single Fan and Multiple Fans  . . 10-11
Start-Up Procedure
  Mechanical Component System Verification . . . . . . 12
  Electrical Components System Verification . . . . . . . 12
  System Start-Up Preparation for VGN . . . . . . . . . . . 12
  System Start-Up for VGN . . . . . . . . . . . . . . . . . . 12-13
  Test and Balance for VGN  . . . . . . . . . . . . . . . . . . . . 13
  Calibrating Carel CFM Display with Test and 
     Balance Procedure  . . . . . . . . . . . . . . . . . . . . . . . . 13
VGN Controller  Introduction, Tutorial, Operator Interface 
and Keypad Navigation . . . . . . . . . . . . . . . . . . . . . . . . 14
 Status 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

 On/Off 

Unit 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

  Set Points (Test and Balance) . . . . . . . . . . . . . . . . . . 16
 Clock/Scheduler 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

 Inputs/Outputs 

. . . . . . . . . . . . . . . . . . . . . . . . . . 17-18

 Alarm 

History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

 Technician . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
 Factory 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
VGN Technology Maintenance. . . . . . . . . . . . . . . . . . . 22
VGN Technology Electrical Replacement Parts . . . . . . 22
Maintenance Record  . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Our Commitment . . . . . . . . . . . . . . . . . . . . . . Backcover

Single Fan 

VGN Controller

Multiple Fan 

VGN Controller

Содержание VEKTOR-CS

Страница 1: ...applicable Follow the Canadian Electrical Code CEC in Canada 2 Do not allow the power cable to kink or come in contact with oil grease hot surfaces or chemicals Replace cord immediately if damaged 3...

Страница 2: ...damage during storage These suggestions are provided solely as a convenience to the user INDOOR The ideal environment for the storage of units and accessories is indoors above grade in a low humidity...

Страница 3: ...ure transducer for duct pressure 1 to 4 Fan motor VFD System Components Multiple Fan VGN Controller Pressure Transducer Box Factory mounted on fan 5 Pin Cables 1 per fan Shipped in Pressure Transducer...

Страница 4: ...onduit to VGN controller box 24 VAC fan run contact BMS communications Proper incoming power 4 All wiring by others per local codes Field Wiring GFC Provided Cables NOTE Duct pressure modulation fan s...

Страница 5: ...cable shipped in the pressure transducer box mounted on the fan to the 5 pin threaded bulkhead on the bottom of the nozzle connect the other end to the 5 pin threaded bulkhead on bottom of the pressu...

Страница 6: ...s is consistent during the entire wiring installation fan 1 will require wiring speci c to fan 1 fan 2 will require speci c wiring along with fans 3 and 4 if applicable Fan Run Signal hard wire connec...

Страница 7: ...V REF U4 GND U5 GND VG VG0 Y1 Y2 Y3 Y4 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 IDC1 U6 U7 U8 GND ID9 ID10 ID11 ID12 IDC9 ID13H ID13 IDC13 ID14 ID14H J1 J24 J2 J3 J4 J5 J7 J8 J20 J21 J14 J10 J13 J12 J22 J16 J...

Страница 8: ...llowing equation SURAIR Voltage 10 15 b J is air density which is job site speci c a universal number to use is 075 lbm ft3 c K Factor is listed on a data plate located on the fan body or refer to the...

Страница 9: ...user can set the maximum and minimum nozzle velocities anywhere between 2000 to 4000 FPM and use the BMS to adjust the nozzle outlet velocity User Set Maximum Outlet Velocity 3000 FPM User Set Minimu...

Страница 10: ...10 VGN Technology Wiring Diagram Single Fan COM COM GND 1FNRUN COM COM COM 1SURAR L2 120V 208V 240V 480V GND GND 1SURAR 1NZVDC 1NZFB1 1NZFB2 24V 24V ALM1 ALMCOM TEST FUSE CAREL CONTROLLER FAN 1 FAN 1...

Страница 11: ...1FNRUN 24V 24V COM COM COM 1SURAR FAN 1 FAN 2 FAN 3 FAN 4 L2 120V 208V 240V 480V 2FNRUN 3FNRUN 4FNRUN GND GND GND GND 1SURAR 2SURAR 2SURAR 3SURAR 3SURAR 4SURAR 4SURAR 1NZVDC 2NZVDC 3NZVDC 4NZVDC 1NZF...

Страница 12: ...dure the fan speed will be increased decreased and there will be periods of time when the entire fan system will be shut down prior arrangements must be made with the lab to accommodate these times of...

Страница 13: ...nd balance mode on the Carel 5 Perform desired test and balancing procedures 6 Upon completing the test and balance of the fan system turn the Test and Balance mode off in the Carel NOTE Test and Bala...

Страница 14: ...user to exit the current menu jumping to the Main Menu Up Down The arrow buttons allow the user to scroll through different screens and adjust parameters Alarm Button will blink red indicating an alar...

Страница 15: ...ed in the configuration Fan Run reports the on off status of the fun run input Flow represents the volumetric airflow of the fan U1 Input is the DC voltage measured at universal input 1 associated wit...

Страница 16: ...osition of the nozzle during testing The user may edit this position as needed during the test mode K Value Adjustment allows the user to apply an offset to the factory K Value The result of such an o...

Страница 17: ...nter key to advance the cursor Then use the arrow keys to adjust the setting Press enter Additional fields are provided that allow the user to enter the specifics pertaining to daylight savings time a...

Страница 18: ...00 to 10 00 VDC Analog Output 2 Output 2 94vdc Analog Output 1 Output 2 94vdc Analog Output 3 Output 2 94vdc Analog Output 4 Output 2 94vdc Alarm History ALARM HISTORY The alarm history records and di...

Страница 19: ...obe Adjustment menu only the end screen is displayed Control Loops Because no content exists under the Control Loops menu only the end screen is displayed MANUAL MANAGEMENT Analog Inputs Because no co...

Страница 20: ...econds Restore is used to retrieve the factory settings from memory and overwrite the current configuration Auto Restore is not used and should remain as NO Though almost never used the Factory Delete...

Страница 21: ...not operating and is at minimum area Check actuator power and signal System has an unfavorable negative pressure condition BMS fan control not working properly Check BMS control and determine if condi...

Страница 22: ...ns Look for loose or broken terminals Tighten to required torque for each or replace as necessary Quarterly Inspect Weather Proof Gaskets Inspect all gaskets and look for moisture Replace if necessary...

Страница 23: ...__________________ _________________________________________________ _________________________________________________ Date ___________________Time _____________ AM PM Notes __________________________...

Страница 24: ...dditional safety information This publication can be obtained from AMCA International Inc at www amca org As a result of our commitment to continuous improvement Greenheck reserves the right to change...

Отзывы: