Warranty

Greenheck warrants this equipment to be free from defects in material and workmanship for a period of three years from
the purchase date. Any units or parts which prove to be defective during the warranty period will be replaced at our
option when returned to our factory, transportation prepaid.

Greenheck will not be responsible for any installation or removal costs.

General Maintenance Suggestions

Model SP/CSP ceiling exhaust fans require very little maintenance. But since small problems over time left unchecked
could lead to loss of performance or early motor failure, we do recommend that the unit be inspected periodically (once
or twice a year).

The fan motor and wheel should be checked for dust and dirt accumulations. (See Filters).  Dirt buildup can lead to loss
of performance and motor overheating. Cleaning can be accomplished by brushing off any dust that may have
accumulated. Even filtered units can accumulate build up and should be checked when cleaning filters.

The motor should be checked for lubrication at this time. Lubricate only those motors which have an oil hole provided. A
few drops of all purpose oil (SAE 20) will be sufficient. 

SP-A & CSP-A IOM FS

#461342  Rev 3  September 2003

Copyright © 2003 Greenheck Fan Corp.

Installation Recommendations

Step 1:

Remove Grille (A) by removing the 2 Grille Screws (B). 

Step 2:

Remove Duct Collar
Cover (C) by removing
the 4 Duct Collar
Screws (D).

Step 3:

Discard Grille (A), 2
Grille Screws (B),
and Duct Collar
Cover (C).

Step 4:

Remove the 6
Tinnerman Clips (E) by
twisting them to one side
and pulling straight out. Discard
2 of the 6 Tinnerman clips.

Step 5:

Insert the remaining 4
Tinnerman Clips (E) on
grille opening side.

Step 6:

Place Blower Box
Cover (F) over
Tinnerman Clips (E),
which were inserted
in step 5.

Step 7:

Screw the Blower Box
Cover (F) into place with 4
Blower Box Cover Screws (D).

A

B

C

D

E

F

E

D

Converting to a Cabinet Design

For Model SP-C Only

Conversion from Ceiling to Cabinet Fan

Conversion Kit Parts List:

Qty. of 1 Blower Box Cover

Tools Required

Phillips Head Screwdriver

All SP-C sizes will be shipped with grille and duct collar cover.

SP/CSP models shown are
UL and cUL listed E 33599 