background image

2

Install the Fan

1.

For best performance, choose a location with the shortest possible duct run
and minimum number of elbows.  Do not mount near cooking equipment, as
shown in figure 7.

2.

Attach adjustable mounting brackets to fan, but leave the screws loose until
proper height is determined, as shown in figure 8.  Cut hole to dimensions
shown in Table A:

2a. For frame construction, position unit between joists.

Position brackets such that bottom edge of housing will be flush with finished ceiling,
and tighten the adjustable mounting brackets, as shown in figure 10.

2b. For hanging installations, use Greenheck’s optional vibration isolator kit Part Number

VI Kit.  Using the fan’s standard adjustable mounting brackets and 10 by 32 threaded
rod - by others, hang unit as shown in figure 11.

3.

Installation of ductwork is critical to the performance of the fan as shown in figure 12.
Straight ductwork (1) or ductwork that turns in the same direction as the wheel (2) is
recommended. Ductwork turning opposite the wheel direction (3) will cause
turbulence and back pressure resulting in poor performance.

Note: If round duct is to be used, Model RDC (Round Duct Connector) can be purchased

from Greenheck that bolts in place of the standard square duct connector.

4.

Slide ductwork over the fan’s discharge collar and securely attach it with sheet metal
screws.  Make sure the screws do not interfere with damper operation.  Check damper
to make sure it opens freely. 

Top Mount

Bottom Mount

Brackets can be
used in either
position to adapt to
most mounting
situations

Bottom Mount

Slots in the
brackets
allow fine
adjustment
for flush
fit with
wall/ceiling
opening

Do not install

fan in this area

45º

45º

Installation Recommendations

Fig. 7

Fig. 8

Fig. 10

Table A

Ceiling Openings

Sizes

Fan or Fan/Light

Fan/CRD

SP-A50, A70, A90

10 7/8 x 13 3/8

11 1/8 x 13 7/16

SP-A110, A125, A190

SP-A200, A250, A290, A390

12 1/8 x 14 1/4

12 1/4 x 14 3/8 

SP-A410, A510, A710, A780

14 3/4 x 18 3/8

14 7/8 x 18 7/16

SP-A700

11 7/8 x 23 7/8

12 x 24

SP-A900, A1050, A1410, A1550

14 3/4 x 24

14 7/8 x 24 1/8

Fig. 11

Wire the Fan

1.

Remove wiring cover and wire nuts.  If fan/light combination is being used make
sure the fan plug is connected to the fan receptacle and the light plug is
connected to the light receptacle as shown in figure 13. Then wire unit to the
correct installation type, as shown in 

figure 13a, 13b, and 13c

.

Light Outlet

Fan Outlet

Hot  (Black)

To  switch

To  power
supply

To  ground

Ground  (Green)

Common  (White)

115  volt  light

Light

Hot  (Black)

To  power
supply

Hot  (Black)

Motor

Common  (White)

220/230/240  volt

AIR FLOW

1

(GOOD)

3

(POOR)

2

(GOOD)

Fig. 13

Fig. 12

Hot  (Black)

To  switch
or

  power

To  power
supply

To  ground

Ground  (Green)

Motor

Common  (White)

115/277  volt

13a

13b

13c

2.  

Push all wiring into the unit’s cover and replace wiring cover. 

Отзывы: