Dimensional Data
B
SQ
.
A
SQ
.
C
D
2
1
/
2 in.
Straight-sided Housing
BL
SQ
.
A
SQ
.
CL
D
2
1
/
2 in.
Louvered Penthouse Housing
J
F
J
G
H
A
SQ.
Base of Unit
L
SQ.
K
SQ.
M
M
M
Optional Duct Adapter
Fan
Size
A
SQ.
B
SQ.
BL
SQ.
C
CL
D
F
G
H
J
K
SQ.
L
SQ.
M
Nominal
Filter
Louver
Tiers
Weights
Straight
Sided
Louvered
90
26
35
1
⁄
8
31
7
⁄
8
23
1
⁄
4
25
3
⁄
8
10
1
⁄
4
12
1
⁄
4
10
3
⁄
4
7
5
⁄
8
6
7
⁄
8
24
1
⁄
2
12
1
⁄
4
6
1
⁄
8
(4) 12x20
3
145
126
(660) (892) (810) (591) (645) (260) (311) (273) (194) (175) (662) (311) (156)
(305x508)
(66)
(57)
100
30
41
1
⁄
8
35
7
⁄
8
23
1
⁄
4
25
3
⁄
8
10
1
⁄
4
13
5
⁄
8
11
7
⁄
8
9
1
⁄
16
8
3
⁄
16
28
1
⁄
2
14
1
⁄
4
7
1
⁄
8
(4) 12x25
3
173
146
(762) (1045) (911) (591) (645) (260) (346) (302) (230) (208) (724) (362) (181)
(305x635)
(78.5)
(66)
120
34
47
1
⁄
8
39
7
⁄
8
27
1
⁄
4
29
3
⁄
8
10
1
⁄
4
16
1
⁄
8
13
7
⁄
8
10
1
⁄
16
8
15
⁄
16
32
1
⁄
2
18
1
⁄
4
7
1
⁄
8
(4) 16x25
4
225
180
(864) (1197) (1013) (692) (746) (260) (410) (352) (256) (227) (826) (464) (181)
(406x635)
(102)
(82)
150
40 53
1
⁄
8
45
7
⁄
8
31
1
⁄
4
33
3
⁄
8
10
1
⁄
4
19
1
⁄
8
16
1
⁄
2
11
1
⁄
4
10
7
⁄
16
38
1
⁄
2
20
1
⁄
4
9
1
⁄
8
(8) 16x20
5
336
250
(1016) (1349) (1165) (794) (848) (260) (486) (419) (286) (265) (978) (514) (232)
(406x508)
(152)
(113)
180
46
61
1
⁄
8
5 1
7
⁄
8
34
1
⁄
4
35
3
⁄
8
12
1
⁄
4
22
1
⁄
2
19
1
⁄
2
10
1
⁄
8
11
3
⁄
4
44
1
⁄
2
26
1
⁄
4
9
1
⁄
8
(4) 16x20
5
400
285
(406x508)
(1168) (1153) (1318) (870) (899) (311) (571) (495) (257) (298) (1130) (667) (232)
(4) 20x20
(181)
(129)
(508x508)
200
52
73
1
⁄
8
58
3
⁄
16
39
1
⁄
4
40
3
⁄
8
12
1
⁄
4
23
1
⁄
4
25
1
⁄
4
13
3
⁄
8
14
3
⁄
8
50
1
⁄
2
30
1
⁄
4
10
1
⁄
8
(8) 20x25
6
620
431
(1321) (1857) (1478) (997) (1026) (311) (591) (641) (340) (365) (1283) (768) (257)
(508x635)
(281)
(196)
All dimensions are in inches
(millimeters)
. Pounds
(kg)
.
Machined parts coated with rust preventive should be
restored to good condition promptly if signs of rust
occur. Immediately remove the original rust preventive
coating with petroleum solvent and clean with lint-free
cloths. Polish any remaining rust from surface with
crocus cloth or fine emery paper and oil. Do not destroy
the continuity of the surfaces. Thoroughly wipe clean
with Tectyl
®
506 (Ashland Inc.) or the equivalent. For
hard to reach internal surfaces or for occasional use,
consider using Tectyl
®
511M Rust Preventive, WD-40
®
or the equivalent.
Removing from Storage
As fans are removed from storage to be installed in their
final location, they should be protected and maintained
in a similar fashion until the fan equipment goes into
operation.