BRIDGE BRACKET

PART NO. 711779

DRAWING NO. 89814

1 REQ'D PER ASSEMBLY

3/4" FLAT WASHER

1 REQ'D PER

ASSEMBLY

BASE ASSEMBLY

3.00 in.

3/8-16 SPINLOCK NUT

2 REQ'D PER ASSEMBLY

HANGING BRACKET

PART NO. 710774

DRAWING NO. 85537

3/8-16x3/4 SPINLOCK BOLT

2 REQ'D PER ASSEMBLY

Lifting Instructions

Greenheck's Modular Small Cabinet Fan (MSCF) should be lifted by the factory supplied lifting
lugs or frame rails and a spreader bar to prevent damage from occurring to the equipment (see
figure 1). Avoid twisting or uneven lifting of equipment. Do not lift equipment by coil connections
or headers. The unit must remain upright during lifting. All access doors and panels must be
closed during lifting to avoid damage (see figure 1).

Figure 1

3

Frame Rails
(By others)

Spreader bar

Lifting lugs

The MSCF should be hung by the factory supplied lifting lugs or field supplied frame rails as
shown respectively in figures 2 and 3. The number of hanging brackets used will be determined
by the number of fan modules.

Figure 3

Figure 2

Hanging Instructions

External Mounting Isolation

The MSCF is available with
both external neoprene and
spring isolation options. When
external isolation is selected a
bridge bracket will be
provided to reduce installation
time (see figure 4).

3/4" FLAT WASHER

1 PER ASSEMBLY AS NEEDED

3/8-16 SPINLOCK NUT

2 REQ'D PER ASSEMBLY

3/8-16x3/4 SPINLOCK BOLT

2 REQ'D PER ASSEMBLY

HANGING BRACKET

PART NO. 710774

DRAWING NO. 85537

BRIDGE BRACKET

PART NO. 711779

DRAWING NO. 89814

1 REQ'D PER ASSEMBLY

KET

779

89814

ASSEMBLY

ER

7

LOCK BOLT

SSEMBLY

HANGING ASSEMBLY

Figure 4

Содержание MSCF

Страница 1: ...items are stored inside the unit during shipping Care must be taken during installation to prevent damage to units MODEL MSCF Modular Small Cabinet Fan Installation Operation and Maintenance Manual W...

Страница 2: ...ows panels removed 9 1 1 4 in knockout for recommended electrical wiring penetration or disconnect switch 8 8 8 8 8 7 9 Table of Contents Unit Layout Table of Parts Lifting Hanging Instructions Modula...

Страница 3: ...to avoid damage see figure 1 Figure 1 3 Frame Rails By others Spreader bar Lifting lugs The MSCF should be hung by the factory supplied lifting lugs or field supplied frame rails as shown respectivel...

Страница 4: ...26 38 2 5 3 5 43 45 6 75 26 18 5 6 75 6 75 26 6 6 75 26 50 2 5 3 5 55 50 6 75 26 18 5 6 75 6 75 26 6 6 75 32 50 2 5 3 5 55 65 6 75 32 18 5 6 75 6 75 28 6 6 75 36 50 2 5 3 5 55 85 6 75 32 18 5 6 75 6...

Страница 5: ...nit A B C D E F Size w o Filter w Filter 12 in 24 in Vertical Sloped Hot Water CW DX Fan Motor Total 15 80 107 31 57 34 61 61 145 94 50 144 20 95 126 36 68 41 72 72 171 111 50 161 25 105 140 40 75 45...

Страница 6: ...same as 4 row chilled water coil data see below Fluid enters the coil from the bottom connection In and exits from the top Out In Out Out In NOTE With airflow from left to right the fluid enters the...

Страница 7: ...nnection between the scroll and the discharge of the fan If noise is an issue we recommend using heavy canvas connections on the inlet of the fan Refer to the Troubleshooting section of this manual if...

Страница 8: ...g good duct practices Blower speed too low Check for correct drives and RPMs with catalog data Mixing box dampers closed Open and adjust Dirty or clogged filters Clean or replace Leaks in ductwork Rep...

Страница 9: ...n of water coils with low entering air conditions CONTINUOUS WATER CIRCULATION THROUGH THE COIL AT ALL TIMES IS HIGHLY RECOMMENDED 5 Pipe sizes for the system must be selected on the basis of the head...

Страница 10: ...ilters are installed check by holding up to a light source If light cannot pass through the filter it should be replaced Replacement filters should be of the same manufacturer and size When reinstalli...

Страница 11: ...build up from plugging the drain and causing the drain pan to overflow Inspect twice a year to avoid the possibility of overflow Also drain pans should be kept clean to prevent the spread of disease C...

Страница 12: ...Up Documentation Actual Voltage Hertz Phase Actual Amperage Blower Rotation Correct Air Volume Design cfm Actual cfm Drive Level of fan L or H Fan RPM Range min max 462888 MSCF IOM APRIL 2003 Warrant...

Отзывы: