background image

GREENHECK

   

P.O. BOX 410  SCHOFIELD, WISCONSIN 54476-0410

PH. 715-359-6171

www.greenheck.com

Part #462888

Report any damaged equipment to the shipper immediately!

All units are shipped on a skid or packaged to minimize damage during shipment. The transporting carrier has
the responsibility for delivering all items in their original condition as received from Greenheck. The individual
receiving the equipment is responsible for inspecting the unit for obvious or hidden damage, recording any
damage on the bill of lading before acceptance and filing a claim (if required) with the final carrier. Some
accessory items are stored inside the unit during shipping. Care must be taken during installation to prevent
damage to units.

MODEL MSCF

Modular Small Cabinet Fan 

Installation, Operation and Maintenance Manual

**WARNING**

Disconnect and secure all electrical power to the “OFF” position prior to inspection or servicing. Failure to
comply with this safety precaution could result in serious injury or death.

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or
death. Read the installation, operating, and maintenance instructions thoroughly before installing or
servicing this equipment.

**IMPORTANT**

All factory provided lifting lugs should be used when lifting any unit. Failure to comply with this safety
precaution could result in property damage, serious injury or death.

Содержание MSCF

Страница 1: ...items are stored inside the unit during shipping Care must be taken during installation to prevent damage to units MODEL MSCF Modular Small Cabinet Fan Installation Operation and Maintenance Manual W...

Страница 2: ...ows panels removed 9 1 1 4 in knockout for recommended electrical wiring penetration or disconnect switch 8 8 8 8 8 7 9 Table of Contents Unit Layout Table of Parts Lifting Hanging Instructions Modula...

Страница 3: ...to avoid damage see figure 1 Figure 1 3 Frame Rails By others Spreader bar Lifting lugs The MSCF should be hung by the factory supplied lifting lugs or field supplied frame rails as shown respectivel...

Страница 4: ...26 38 2 5 3 5 43 45 6 75 26 18 5 6 75 6 75 26 6 6 75 26 50 2 5 3 5 55 50 6 75 26 18 5 6 75 6 75 26 6 6 75 32 50 2 5 3 5 55 65 6 75 32 18 5 6 75 6 75 28 6 6 75 36 50 2 5 3 5 55 85 6 75 32 18 5 6 75 6...

Страница 5: ...nit A B C D E F Size w o Filter w Filter 12 in 24 in Vertical Sloped Hot Water CW DX Fan Motor Total 15 80 107 31 57 34 61 61 145 94 50 144 20 95 126 36 68 41 72 72 171 111 50 161 25 105 140 40 75 45...

Страница 6: ...same as 4 row chilled water coil data see below Fluid enters the coil from the bottom connection In and exits from the top Out In Out Out In NOTE With airflow from left to right the fluid enters the...

Страница 7: ...nnection between the scroll and the discharge of the fan If noise is an issue we recommend using heavy canvas connections on the inlet of the fan Refer to the Troubleshooting section of this manual if...

Страница 8: ...g good duct practices Blower speed too low Check for correct drives and RPMs with catalog data Mixing box dampers closed Open and adjust Dirty or clogged filters Clean or replace Leaks in ductwork Rep...

Страница 9: ...n of water coils with low entering air conditions CONTINUOUS WATER CIRCULATION THROUGH THE COIL AT ALL TIMES IS HIGHLY RECOMMENDED 5 Pipe sizes for the system must be selected on the basis of the head...

Страница 10: ...ilters are installed check by holding up to a light source If light cannot pass through the filter it should be replaced Replacement filters should be of the same manufacturer and size When reinstalli...

Страница 11: ...build up from plugging the drain and causing the drain pan to overflow Inspect twice a year to avoid the possibility of overflow Also drain pans should be kept clean to prevent the spread of disease C...

Страница 12: ...Up Documentation Actual Voltage Hertz Phase Actual Amperage Blower Rotation Correct Air Volume Design cfm Actual cfm Drive Level of fan L or H Fan RPM Range min max 462888 MSCF IOM APRIL 2003 Warrant...