Version 5 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp
Page 14 of 27
3.4 Hub supply cable termination (CE)
Connect the P2M Connector to a 3-core adequately rated mains supply cable by inserting into the screw terminals
as shown below. Ensure there are no frayed copper strands and the supply is adequately protected to meet all local
wiring regulations. Not applicable if installing a Greengage Power Hub Panel.
3.5 Hub supply cable termination (UL)
Connect the IEC C13 Connector to a 3-core adequately rated mains supply cable by inserting into the screw
terminals as shown below. Ensure there are no frayed copper strands and the supply is adequately
protected to meet all local wiring regulations.
3.6 System Connection
a.
Connect the ALIS Bus to the ALIS Dimmer as shown in the ALIS system components diagram (page 5).
b.
Connect the ALIS Dimmer to the ALIS Power Hub as shown in the ALIS system components diagram
(page 5).
c.
Connect the selected dimming control method to the ALIS Dimmer. Dimming is possible via either an ALIS
Dimmer Pot or a 0-10VDC control signal, ensuring polarity is maintained, as shown in the ALIS system
components diagram (page 5).
Connecting ALIS Dimmer to ALIS Pot/0-10VDC (Not applicable if installing the Greengage Power Hub Panel).
Connectors of the same shape can be connected.
Multiple ALIS Dimmers can be controlled with a single ALIS Pot, Greengage DTD Controller or another
0-10VDC supply.
The potentiometer connection to the hub can also be used to extinguish the lamps via the use of a timer
switch or on/off switch, which avoids the necessity of disconnecting the mains supply.
Please contact [email protected] for additional information as required.
Blue
Yellow/Green
Brown