Greengage ALIS Скачать руководство пользователя страница 11

1 October 2018 

Version 5 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp 

 Page 10 of 27 

Once the ALIS Bus is positioned within the coupler housing, carefully bring the two lid sections together and close. 

It is recommended to close the end clips first and then close the side clips by pressing on their outside surfaces 

rather than the thumb levers. 

  

Ensure that the ALIS Bus is not trapped when closing the coupler and the ALIS Barn Lamp ferrite surfaces 

are clean and free from grit. 

 

 

Ensure a minimum 3cm (1

¼

 inches) of ALIS Bus remains untwisted at the coupler entry holes. Too tight  

a twist at this point can cause a lift in the coupler lid resulting in a broken seal. 

 

 

Attach all the remaining ALIS Barn Lamps to the desired position along the ALIS Bus. Once completed, cable tie the 

ALIS Bus to the catenary wire.  

 

Place the first two cable ties a minimum of 20 cm (8 inches) each side of the ALIS Coupler ensuring the 

catenary wire supports the ALIS Barn Lamp on its clip. Add the remainder of the cable ties between 30cm 

to 40cm (12 to 16 inches) apart to ensure the ALIS Bus does not droop at any point. 

 

 

2.2 ALIS Nest Lamp  

Reference sections 1. and 6. of this manual and the lamp positioning information, found within the lighting design 

plan. If there is not any positioning information available, then fit to achieve the required lighting level within the 

nest box. Take note of the lamp position and place the first lamp as follows. At the desired lamp position un-twist, 

the ALIS Bus by no more than 5cm (2 inches). Place one wire from the ALIS Bus into the lamp coupler slot, as 

shown below, ensuring the ALIS Bus is clean and free from grit. 

 

                

            

 

 

Without untwisting the ALIS Bus any further, as the cable twist tension is used to hold the lamp in place, slide the 

second wire over the lamp housing as shown below, locating and pressing the ALIS Bus wire firmly within the guide 

clip channel. 

 

Ensure the first wire has remained fully inserted within the coupler lamp slot. Attach all the remaining ALIS Nest 

Lamps to the desired position along the ALIS Bus. 

 

 

 

Содержание ALIS

Страница 1: ...Version 5 1 CE and UL www greengage global PATENTED INDUCTION POWERED TECHNOLOGY BY Greengage www greengage global patents Installation Manual ALIS power control and lighting platform...

Страница 2: ...Page 1 of 27 Version 5 1 CE and UL ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018 ALIS Barn Lamp best practice clip on procedure...

Страница 3: ...on site and installers should contact Greengage Lighting Ltd technical support with any queries they may have at support greengage global Please follow these instructions carefully as deviation from...

Страница 4: ...eral Guidance 11 3 1 ALIS bus termination 11 3 2 End termination 12 3 3 End termination rules 13 3 4 Hub supply cable termination CE 14 3 5 Hub supply cable termination UL 14 3 6 System Connection 14...

Страница 5: ...on Other tools may be required depending on the exact suspension mounting method used and the composition of the surface mounting material Tape Measure Screwdrivers inc terminal driver Cable cutters c...

Страница 6: ...ALIS Bus to the ALIS lamps This document serves as guidance for an ALIS installation within an intensive livestock rearing building Installers must also follow all applicable local electrical install...

Страница 7: ...Type USE 2 cable or Type RHH 2 wire marked VW 1 14AWG standard type rated 90 C min and 300V minimum 3 ALIS Barn Lamp Wide Beam ALS0003 ALS0003 Suitable for wet location use Do not submerse IP66 4 ALI...

Страница 8: ...nclosure to meet local regulations 9 ALIS Bus End termination module and enclosure ETM ETM Must be housed within a suitably sealed enclosure IP66 see section 3 2 10 P2M Supply Connector P2M N A Not ap...

Страница 9: ...mechanical fitting at an early stage with either the house builder or architect to ensure that correct placement of the ALIS lamps within the house is possible If not a redesign of the lighting plan m...

Страница 10: ...meets local wiring regulations Due to the heat generated by the ALIS Power Hub please contact support greengage global for further advice if required 2 Lamp connection 2 1 ALIS Barn Lamp Reference th...

Страница 11: ...y wire supports the ALIS Barn Lamp on its clip Add the remainder of the cable ties between 30cm to 40cm 12 to 16 inches apart to ensure the ALIS Bus does not droop at any point 2 2 ALIS Nest Lamp Refe...

Страница 12: ...of the ALIS Bus to 30mm 1 inches taking care not to damage the inner insulation Strip the ends of the ALIS Bus inner insulation to 8mm 0 3 inch of exposed conductor ensuring there is not any conducto...

Страница 13: ...insulation must be properly stripped to ensure there is no to damage the cable conductors Strip the ends of the ALIS Bus to 5mm 0 2 inch of exposed conductor ensuring there is not any conductor loss...

Страница 14: ...rved If the length of the ALIS bus is less than 100m then the ALIS Bus must be terminated by means of a shorting connection to keep the ALIS Bus in resonance with the Hub When the length is greater th...

Страница 15: ...the ALIS Dimmer as shown in the ALIS system components diagram page 5 b Connect the ALIS Dimmer to the ALIS Power Hub as shown in the ALIS system components diagram page 5 c Connect the selected dimmi...

Страница 16: ...erly terminated 4 Ensure the ALIS Dimmer is properly connected to the ALIS Bus 5 Ensure the ALIS Dimmer is properly connected to the ALIS Power Hub 6 Ensure the control cable ALIS Dimmer Pot or indepe...

Страница 17: ...hen input supply exceeds 270 VAC for a 230VAC ALIS Power Hub or Automatic lockout when input supply exceeds 132 VAC for a 120VAC cULus ALIS Power Hub The ALIS Power Hub resets when supply returns to n...

Страница 18: ...here is an adequate mains supply present Once the correct supply voltage level is ascertained attempt a power up reset If this does not resolve the fault carrying out the check list on page 15 before...

Страница 19: ...situation arise please ensure that all ends are sealed and lids correctly fitted to stop fauna rodent ingress 8 Installations should never use no more than the required length of ALIS Bus for each AL...

Страница 20: ...minal Maximum Power Rating 230VAC CE Max Power 500W Power Rating 120VAC cULus Max Power 475W Load Regulation 0 500W Output 0 95 1 45 1 95 O P Frequency ALIS Bus 49 kHz 50 kHz 51 kHz O P Current ALIS B...

Страница 21: ...uitable for Wet Locations Do not Submerse Rated Life 100 000 Hours Ambient Temperature 20 to 55 C Humidity Range 0 to 95 7 4 ALIS Nest Lamp Parameter Specification Light Source 0 3W High Power LED 300...

Страница 22: ...its Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection 2013 E...

Страница 23: ...exposure to electromagnetic fields 2015 EN 60598 1 Luminaires Part 1 General requirements and tests 2015 EN 60598 2 4 Luminaires Particular requirements Portable general purpose luminaires 1998 EN 613...

Страница 24: ...and Warranty Registration Greengage Lighting Limited Sir Alexander Robertson Building University of Edinburgh Easter Bush Campus Midlothian EH25 9RG United Kingdom Date of Installation Site Informati...

Страница 25: ...27 Install Information ALIS Power Hub Serial Number ALIS Dimmer Serial Number Length of Cable Number of ALIS Barn Lamps Dimming Facility ALIS Pot 0 10VDc Pictures Please send pictures of the following...

Страница 26: ...Page 25 of 27 Version 5 1 CE and UL ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018 Appendix Connection diagram...

Страница 27: ...1 October 2018 Version 5 CE and UL ALIS Barn Lamp and ALIS Nest Lamp Page 26 of 27 Notes...

Страница 28: ...Page 27 of 27 Version 5 1 CE and UL ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018...

Отзывы: