The stove has the following four safety systems:
1. Thermal protection shuts down the stove if the temperature in the wood pellet tank becomes
too high (85°C).
2. The thermal sensor in the pellet tank activates at 82°C and automatically reduces
the heat level. If this fails to achieve a drop in temperature, the thermal protection (1) is activated.
3. The pressure sensor measures whether there is sufficient draught in the chimney. If problems with
inadequate draft or a blocked chimney arise, the pressostat shuts down the stove.
4. The door switch shuts down the stove if the door is opened during operation.
5.1 Temporary power failure
If the power failure only lasts a few seconds, the stove will restart and function normally. The
control system automatically shuts down the stove in the event of protracted power failure. The
duration of the shutdown phase may vary greatly, depending on the stove temperature.