Greenfire GF40-2 Скачать руководство пользователя страница 5

DATE OF MANUFACTURE / 

DATE DE FABRICATION

 

:

J    F     M    A   M   J    J    A    S    O    N    D

20

2

2

    

202

3

    

202

4

CAUTION:

Hot while operating. 

Do not touch, severe 

burns may result. Keep 

children, clothing, 

furniture, gasoline or 

other  flammable 

vapors away

See installation and operating 

instructions accompanying 

appliance. 

ATTENTION

 

:

Appareil très chaud 

lorsqu'il est en marche. Ne 

pas toucher pour éviter de 

sévères brûlures. Tenir à 

distance les enfants, les 

vêtements, les meubles, 

l’essence ou autres fluides 

produisant des vapeurs 

inflammables.

Consulter le manuel d’installation et 

d’utili

sation.

INSTALLED AS A FREESTANDING STOVE MODEL (FS) /

À

 INSTALLE

R

 COMME UN MOD

È

LE

 DE POÊLE AUTOPORTANT

 

Minimum clearances to combustible materials; conventional 

or mobile home./ 

Dégagements minimaux par rapport aux 

matériels combustibles

 :

 maison conventionnelle ou mobile.

C-15527

LIGHTING INSTRUCTIONS:

-Press and release the on  /  off button

-Once fire has started, set the heat output to the desired setting.

 

TO 
TURN 

THE UNIT 

OFF:

-Push the on  /  off button

(Refer to owners manual for detailed instructions)

CONSIGNES D

’ALLUMAGE

 

:

-

Appuyer sur le bouton on/off (marche/arrêt), puis le relâcher

.

-

Une fois que le feu a démarré, régler la sortie de chaleur au n

iveau

désiré.

POUR 

É

TEINDRE L’

APPAREIL 

:

-

Appuyer sur le bouton on/off.

(Se reporter au manuel d’utilisation pour des consignes détaill

ées.)

 

For Use With Only Pelletized Wood fuels. Operate only with viewing door and ash removal door closed. Only 

replace glass with ceramic glass. Components required for installation:  a  3 inch (75 mm) or 4inch (100 mm) 

listed PL vent, complete with components. Hearth mount installations; a listed single wall chimney liner may 

be used.  Inspect and clean Exhaust Venting system frequently.

À utiliser avec des combustibles sous forme de granules uniquem

ent. Faire fonctionner seulement avec la 

porte de visualisation et la porte de retrait des cendres compl

ètement fermées. Remplacer seulement la vitre 

par une vitre en c

é

ramique. Composants requis pour l'installation : ventilation PL

 approuvée de 3 pouces (75 

mm) ou 4 pouces (100 mm) avec pièces. Installations de montage 

de foyer; une doublure approuvée de 

cheminée à simple paroi peut être utilisé

e

. Inspecter et nettoyer fréquemment le système d'évacuation.

 

This wood heater needs periodic inspection and repair for prope

r operation. Consult the owner’s manual 

for further 

information. 

It 

is 

against 

federal 

regulations 

to 

operate 

this 
wood 

heater 

in 

manner 

inconsistent with the operating instructions in the owner’s man

ual. U.S. ENVIRONMENTAL 

PROTECTION AGENCY Certified to 

comply 

with 

2020 

particulate 

emission 

standards. 

Under 

specific 

test 

conditions 

this 
heater 

has 

been shown to have a particulate emission level of .

54

 g/hr. Ce poêle à

 

granules doit être périodiquement inspecté et réparé pour un fo

nctionnement correct. Consulter le 

manuel d'utilisation pour plus d'information. Il est contraire 

à la règlementation fédérale de faire 

fonctionner ce poêle d'une manière non conforme aux consignes d

'utilisation figurant dans le manuel. Ce 

poêle répond aux normes 2020 en matière d'émissions de particul

es de l'Environmental Protection 

Agency des États-Unis. Dans des conditions de test spécifiques,

 ce poêle a montré un niveau d'émission 

de particules de 0

,54
 g/h.

4001609

Certified for use in Canada & USA

 

Certifié pour 

une 

installation au 

Canada et aux 

É

tats-Unis.

Manufactured in Canada for / 

Fabriqué 

au

 Canada pour

 

:

FPI Fireplace Products International Ltd.

 

Delta, BC, Canada

DO NOT REMOVE THIS LABEL

N

PAS

 ENLEVER

 CETTE 

É

TIQUETTE

OUTPUT Rating

/Puissance de sortie 

:  6,

881

 to 

23

,

892

 BTU/Hr 

(

2.01

 to 

7

.

00

 kWh)  

559

 B 

 A 

 C 

8"     (200 mm)

5.5"  (140 mm)

4"  (100 mm)

A)

 Sidewall to unit / D

u

 mur lat

é

ral à l'

appareil

B)

 Backwall to unit / D

u

 mur du fond à l'

appareil

C)

 Backwall to Chimney Connector /

 Du mur du fond

au 

raccordement

 de cheminée

D)

 Corner to unit / Du coin à l'

appareil

3"  ( 75 mm)

E) If supplied Hearth Pad is used no floor protection is required. If unit is installed 

on a 

combustible floor and the supplied Hearth Pad is not used the floor must 

be protected by a certified non-combustible Hearth Pad extending 6 inches (150 

mm) in front of the glass. /

Si le protecteur de plancher fourni est utilisé, aucune 

autre protection n'est requise. Si l'appareil est installé sur 

un plancher 

combustible et que le protecteur de plancher n'est pas utilisé,

 le plancher 

combustible doit être protégé par un matériel  non combustible 

certifié 

s'étendant sur 6 pouces (150

 mm) à l'avant de la vitre.

 

ALCOVE

Largeur 

min. 

/ Width Minimum 

            

36" (915 mm)

Hauteur 

min. 

/ Height Minimum           

48" (1220 mm)

Profondeur

 min. 

 / Depth Minimum

          30" (760 mm)

 D 

GREENFIRE MODEL / MODELE : 

GF40

-2

Listed Room Heater, Pelletized Fuel 

Type (Appareil de chauffage à granules certifié)

Suitable For Mobile Home Installation (

Approuvé pour installation dans une 

 maison mobile)

Certified to (

certifi

é): 
ASTM E1509-12,  

 

ULC 

S6

27-00 

Refer to Intertek’s Directory of Building Products for detailed information. / Reportez-vous 

à l'

Annuaire des 

produits du bâtiment 

de Intertek 

pour obtenir des informations détaillées.

This pellet appliance has been tested and listed for use in manufactured homes in accordance with Oregon 

Administration Rules 814-23-900 through 814-23-909. Install and use only in accordance with the Manufacture’s 

installation and operating instructions. Contact local building or fire officials about restrictions and installation 

inspection in your area. Do not connect this unit to a chimney flue serving another appliance. See local building 

codes and manufacturers instructions for precautions required for passing a chimney through a combustible wall 

or ceiling. Electrical rating: 120 volts, 60 hz, 4.1  Amps. Route cord away from the heater.

Cet appareil à granules a été testé et répertorié pour une util

isation dans les maisons préfabriquées 

conformément aux règlements du gouvernement de l’Oregon, de 814

-33-900 à 814-23-909. Installer et utiliser 

uniquement conformément aux consignes d’installation et d’utili

sation du fabricant. Contacter les autorités 

locales de la construction ou de la protection incendie pour s'

informer sur les restrictions et l’inspection de 

l’installation au niveau local. Ne pas brancher cet appareil su

r un conduit de cheminée utilisé pour un autre 

appareil. Consulter les codes de construction locaux et les con

signes du fabricant pour les précautions 

nécessaires à prendre pour faire passer une cheminée à travers 

un mur ou un plafond combustible. Puissance 

électrique : 120 volts, 60 Hz, 4,1 A. Maintenir le câble à l’éc

art de l’appareil de chauffage.

920-411

PFS TECO

REPORT 

#21-694

E

This is a copy of the safety label that accompanies each 

GF40 . We have printed a copy of the contents here for 

your reference.

On the GF40 the safety label is located on the underside 

of the hopper lid.

 

GF40 Freestanding Pellet Stove  |     

5

5

safety decal

Содержание GF40-2

Страница 1: ...must be performed by an authorized installer or service agency Tested by Greenfire GF40 2 OWNER S INSTALLATION MANUAL Freestanding Pellet Stove Contact your building or fire officials about restrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT...

Страница 2: ...NG This pellet heater needs periodic inspection and repair for proper operation It is against federal regulations to operate this pellet heater in a manner inconsistent with operating instructions in this manual WARNING This wood pellet has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this pellet heat...

Страница 3: ...ntal Exhaust Through Wall Installation 17 Through Wall Vertical Rise Horizontal Termination Installation Freestanding 18 Inside Vertical Installations 19 Outside Vertical Installations 19 Hearth Mount Installation 20 Top Vent Adaptor Kit 3 to 6 Flue Adaptor 21 Thermostat Install 21 OPERATING INSTRUCTIONS Control Board Functions 23 Automatic Safety Features 23 Operating Your Pellet Stove 24 Turning...

Страница 4: ... Capacity up to 67 lb 28 Kg Voltage 110 120 V Max Current 4 1 Amps Consumption on High 3 1 lb hr 1 4 Kg hr Consumption on Low 1 3 lb hr 0 6 Kg hr Note Consumption will vary with the type of fuel used 4 GF40 Freestanding Pellet Stove 4 dimensions ...

Страница 5: ...fié pour une installation au Canada et aux États Unis Manufactured in Canada for Fabriqué au Canada pour FPI Fireplace Products International Ltd Delta BC Canada DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE ÉTIQUETTE OUTPUT Rating Puissance de sortie 6 881 to 23 892 BTU Hr 2 01 to 7 00 kWh 559 B A C 8 200 mm 5 5 140 mm 4 100 mm A Sidewall to unit Du mur latéral à l appareil B Backwall to unit Du ...

Страница 6: ...vels can result in loss of consciousness and death Do not burn with insufficient combustion air A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber Setting the proper combustion air is achieved by adjusting the slider damper located on the left side of the stove When installing the stove in a mobile home it must be electrically grounded to the stee...

Страница 7: ...f the house to see if any part has become hot enough to catch fire If necessary spray with fire extinguisher or water from the garden hose IMPORTANT Do not operate the stove again until you are certain the chimney and its lining have not been damaged FUEL This pellet stove is designed and approved to only burn wood pellet fuel with up to 3 ash content Dirty fuel will adversely affect the operation...

Страница 8: ...UIDS Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in the heater Keep all such liquids well away from the heater while it is in use SMOKE DETECTOR Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning appliance OPERATION The ash pan and door must be closed s...

Страница 9: ... 3 maximum Standard grade Moisture Content 8 maximum Heat Content approximately 8200 BTU per pound minimum ASH The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning The use of high ash fuels may result in the stove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING Clinkers are silica sand or other i...

Страница 10: ...equire a grounded extension cord to reach the nearest electrical outlet The use of a surge protected power bar is highly recommended 7 Stove must sit on a non combustible pad that extends six inches in front of the door or the included hearth pad GF40 025 Removing Your Pellet Stove From the Crate 1 Start by removing the crating and unit bag you will need a pry bar and hammer to remove the crating ...

Страница 11: ...ad must be used when on combustible material A certified non combustible Hearth Pad with a minimum R Value of at least 0 84 must be placed underneath the unit and extend six inches in front of the unit measured from the glass If the GF40 is installed on carpet the use of a solid non combustible Hearth Pad must be used under leveling legs Figure 2 Hearth Pad Install Hearth Installation GF40 Freesta...

Страница 12: ...es are for the safety of the property To avoid overheating and damaging the appliance these clearances should be maintained for non combustibles also A Side wall to unit 8 inches 200 mm B Back wall to unit 5 1 2 inches 140 mm C Back wall to Chimney Connector 4 inches 100mm D Corner to unit 3 inches 75 mm E Glass to Hearth Pad 6 inches 150 mm F Glass to Hearth Pad 7 3 8 inches 187 mm Figure 3 Minim...

Страница 13: ...imes Be sure to leave room for servicing routine cleaning and maintenance These are inside dimensions Minimum Alcove Width 36 inches 915 mm Minimum Alcove Height 48 inches 1220 mm Minimum Alcove Depth 30 inches 762 mm Alcove Clearances Figure 4 Minimum Alcove Clearances GF40 Freestanding Pellet Stove 13 13 installation ...

Страница 14: ...t no guarantee against such incidents NOTE Venting terminals shall not be recessed into walls or siding Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any other combustible materials B 48 in 122 cm Beside below any door or window that may be opened 18 46 cm if outside fresh air installed C 12 in 30 cm Above any door or window that may be opened 9 23 cm if outs...

Страница 15: ...ling legs are adjusted Outside Fresh Air Connection Outside fresh air is mandatory when installing this unit in airtight homes R2000 and mobile homes A Fresh air intake is strongly recommended for all installations Failure to install a fresh air intake may result in improper combustion as well as the unit smoking during power failures When connecting to an outside fresh air source do not use plast...

Страница 16: ...ndatory Secure outside air connections directly to fresh air intake pipe and secure with three screws evenly spaced CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Figure 8 Mobile Home Installation Minimum clearances must be maintained for a corner installation as shown in figure 9 GF40 1 4 Lag Bolts Securely Fastened Ground Wire Directly to...

Страница 17: ...t hole size and clearance to combustibles 5 Install the wall thimble as per the instructions written on the thimble Maintain an effective vapour barrier in accordance with local building codes 6 Install a length of 3 75 mm or 4 100 mm vent pipe into the wall thimble The pipe should install easily into the thimble 7 Connect the exhaust vent pipe to the exhaust pipe on the stove Seal the connection ...

Страница 18: ...e to the back pressure in the exhaust caused by airflow around the structure Follow vent manufacturer guidelines for installation of venting High temp sealant must be used when connecting vent pipe to the unit s starter pipe Improper seals at the vent joints may cause combustion by products to leak into the room where installed seal as required Through Wall Vertical Rise Horizontal Termination Ins...

Страница 19: ...extend the pellet vent to go through the roof flashing 7 Ensure that the rain cap is approximately 24 600 mm above the roof 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rai...

Страница 20: ...Hearth Mount Installation Combustible Floor Masonry Fireplace Steel Plate or Flashing Flexible or Rigid 6 Stainless Steel Liner 10 25 4 cm Mantel Minimum 8 20 cm from top of stove Damper Removed or Fastened Open Clean out tee Flue Connector Min 6 15cm Hearth pad or other floor protection Rain cap Storm collar Seal plate cover plate Existing masonry flue Vent pipe single wall stainless flex pipe or s...

Страница 21: ...a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat If the unit has been placed in the HI LOW mode the unit will be taken to a low or idle setting when the thermostat is not calling for heat When the thermostat calls for heat the unit will go to the setting that is displayed on the control board Heat Indicator Connect Thermostat wires here Thermostat Wire Placemen...

Страница 22: ... away from the unit Once the harness is unplugged you can easily access the circuit board and will be able to attach the thermostat wires to the thermostat connection shown in Figure 26 4 Use a small flat head screwdriver to tighten and secure the wires The wires should be run through the plastic bushing located at the back of the stove opposite side from the power cord 5 Reverse steps 3 1 Figure ...

Страница 23: ...and Off 7 ROOM AIR FAN ON OFF BUTTON Used to turn convection fan On or Off 8 HEAT LEVEL ADJUSTMENT BUTTONS When pressed will change the heat level setting of the unit up or down 9 HEAT OUTPUT INDICATOR Shows the present heat output setting Automatic Safety Features of Your Pellet Stove A The stove and insert have a low limit safety switch located on the housing of the exhaust blower If the exhaust...

Страница 24: ...ove Off MANUAL and HI LOW mode To turn the unit OFF simply press the ON OFF button This will stop the feed of pellets The blowers will continue to operate and cool the stove down When cool enough the stove will turn off AUTO OFF mode To turn the unit OFF turn the thermostat down or off NOTE The unit will run on low for three 3 minutes before it turns off C The unit is equipped with a vacuum switch...

Страница 25: ...reating clinkers hard silica ash build up Guidelines For Fine Tuning For Fuel Quality Due to fuel quality the slider damper and control board trims may need to be fine tuned 1 If the unit builds up on all settings the slider damper rod should be pulled out in small increments to give the unit more air 2 If the unit has excesses ash build up in the liner on the lower feed settings the Combustion Bl...

Страница 26: ...rflows the burn pot or there is a build up of clinkers this is an indication that the pellet fuel quality is poor the stove may need cleaning or the air adjusted Check the stove for ash build up clean if required and adjust the damper to produce the proper clean combustion HEAT EXCHANGER TUBES 2 3 days A rod is located in the center of the stove just above the door behind the top louvers see Figur...

Страница 27: ...les Monitor the ash level of the firebox every week and vacuum out as needed Remember that different pellet fuels will have different ash contents Ash content is a good indication of fuel efficiency and quality Refer to Safety Warnings And Recommendations for disposal of ashes Vacuum the inside of the ash pan compartment inside the pedestal including the hole at the top back of the compartment Rep...

Страница 28: ... penetrating oil Remove the four screws that hold the side panels in place With the tip of a flat screwdriver gently lift up the side panels and remove the side panels Pull the center panel out Vacuum thoroughly Re install panel by inserting center panel Place the side panels back into the firebox locking them into place and re install the two screws on each side Clean thoroughly Note Screws that ...

Страница 29: ...re working properly You may use high temp anti seize on door hinges for smoother operation POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be thoroughly cleaned and serviced Pellet stove should be regularly service for optimum efficiency and prolonged life DOOR GLASS REPLACEMEN...

Страница 30: ...er for fuel Incorrect air damper setting Excessive air may consume the fire too quickly before the next drop of fuel leaving completely unburned fuel in the burn pot liner Insufficient air will cause build up further restricting the air flow through the Burn Pot Liner This in turn will cause the fuel to burn cold and very slowly Fuel may build up and smother the fire In this case clean the burn po...

Страница 31: ...n replace the Combustion Blower To reset Circuit Board after a trouble code push the ON OFF button 5 Auger light flashes but auger motor does not turn at all If the Auger gear box does not turn but the motor s armature does try to spin then the auger is jammed Try to break apart jam by poking at the jam through the drop tube If this fails then empty the hopper and remove the Auger Cover Remember t...

Страница 32: ... slightly poor quality pellets will require slightly higher settings If the stove goes out and there are partially burned pellets left in the burn pot liner the stove has shut down due to a lack of air exhaust temperature or power failure Adjust the Slider Damper Adjust the trim settings Check to see if the stove needs a more complete cleaning Turn the Heat Level up slightly poor quality pellets w...

Страница 33: ...llow Grey Grey Grey Grey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Armor Cable Supplied Vacuum Switch Combustion Blower Optional Exterior Exhaust Blower Power Cord Ground Ignitor Exhaust Temperature Sensor 5 Amp Fuse High Limit Temperature Sensor Convection Blower Auger Motor Common Hot Thermostat GF40 Freestanding Pellet Stove 33 33 maintenance ...

Страница 34: ...094 CONTROL PANEL DECAL 16 GF40 016 AUGER 17 GF40 017 HEAT EXCHANGER SCRAPER ROD 18 GF40 018 DRAFT SLIDER 19 GF40 019 DOOR HINGE BRACKET 20 GF40 021 BURN POT LINER 21 GF40 020 BURN POT 22 GF40 022 ASH PAN 23 GF40 023 INNER DOOR 24 GF40 024 OUTER DOOR 25 GF40 025 HEARTH PAD 26 GF40 026 CABINET SIDES L R 27 GF40 027 BOTTOM CABINET SIDE BRACKETS 28 GF40 029 TOP CABINET SIDE BRACKETS 29 GF40 030 OUTER...

Страница 35: ... SCRAPER TOOL 48 GF55 048 CLEANING BRUSH 50 920 412 GF40 USERS MANUAL 51 GF40 012 DOOR GASKET ROPE 52 936 299 ASH PAN GASKET SOLD PER FOOT 4 FEET REQUIRED 53 GF55 015 COMBUSTION BLOWER MOUNTING GASKET 54 GF55 016 COMBUSTION BLOWER GASKET 55 GF40 920 TOP VENT ADAPTOR KIT 56 GF40 054 ASH COVER PLATE N S GF40 053 MINI BACKDRAFT FLAP WITH OVAL GASKET N S 3PVP X6 3 76 MM TO 6 152 MM FLUE INCREASER SIMP...

Страница 36: ...36 18 37 19 33 32 23 24 22 21 20 35 25 26 27 28 29 34 30 38 37A 51 52 GF40 STEEL 36 GF40 Freestanding Pellet Stove 36 parts list 55 56 GF40 STEEL 36 GF40 Freestanding Pellet Stove 36 parts list ...

Страница 37: ...9 3 1 17 13 12 11 10 5 4 8 2 7 15 14 16 GF40 Components 6 GF40 COMPONENTS GF40 Freestanding Pellet Stove 37 37 parts list ...

Страница 38: ...nly unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective part is returned to the distributor dealer or agent for inspection if requested by FPI Alternatively FPI may at its own discretion full...

Страница 39: ...axed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are not covered under the terms of this Limited Lifetime Warranty FPI has no obligation to enhance or modify any unit once manufactured i...

Страница 40: ...onal terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and telephone contact info...

Страница 41: ...ion Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA FPI Fireplace Products International Ltd ...

Страница 42: ...42 GF40 Freestanding Pellet Stove 42 warranty ...

Страница 43: ......

Страница 44: ...______________________________________________________ Phone __________________________________________________________________ Date Installed _____________________________________________________________ Serial __________________________________________________________________ Printed in Canada Greeenfire is a trademark of Fireplace Products International Ltd Copyright 2022 Regency Fireplace Prod...

Отзывы: