minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The convection
blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output
indicator. The convection blower can be turned OFF by depressing the convection blower control button. For the
best efficiency the convection blower should be left on at all times.
HIGH/LOW MODE:
(Requires a thermostat) INITIAL START-UP: See manual mode above.
OPERATION:
When the thermostat calls for heat (contacts are closed) the stove settings are adjustable as per
Manual Mode. When the thermostat contacts open, the HEAT LEVEL and Fans will drop down to the LOW setting
until the thermostat contacts close again. *The LOW heat setting can be adjusted for different fuel qualities (see
“Operating Instructions - Control Board Functions”). The stove will come back to the previous HEAT LEVEL setting
when the thermostat contacts close again.
AUTO/OFF MODE:
(Requires a thermostat) INITIAL START-UP: See manual mode above.
OPERATION:
When the thermostat contacts close, the unit will light automatically. Once up to temperature, the
stove operates the same as in MANUAL. When the thermostat contacts open, the stove’s HEAT LEVEL and Fans will
drop down to the LOW setting for 30 minutes. If the thermostat contacts close within the 30 minutes, the HEAT
LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open the stove automatically
begins its shutdown routine. The ON / OFF button can be pressed at any time the the stove will immediately shut
down. The stove will relight when the thermostat contacts close again.
t
urnIng
y
our
p
ellet
S
tove
o
ff
• MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed
of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will
turn off.
• AUTO / OFF mode: To turn the unit OFF, turn the thermostat down or off. NOTE: The unit will run on low for
three (3) minutes before it turns off.
C. The unit is equipped with a vacuum switch to monitor the venting pressure; if it becomes blocked or the combustion fan
fails the vacuum switch will turn off the auger and there will be an
#2
flashing error code.
o
peratIon
y
our
p
ellet
S
tove
PRE-BURN INSTRUCTIONS
: The burn pot liner holes must be clear and the liner installed properly against
the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board. To START: Press the ON / OFF button. The
stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the auger (the Auger
Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove
will run at after start-up and can be adjusted but the change will not take affectuntil the start -up has finished.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed.
This can be done by restarting the unit five (5) minutes into its start-up or by putting a small hand full of pellets
into the burnpot.
TO OPERATE:
When a fire has been established, the System Light will turn solid (after approximately 10 - 15
NEVER unplug a unit that is running!
DO NOT unplug unit while Combustion fan is running.
Unplugging may cause smoke to be released into the home.
24
| GF40 Freestanding Pellet Stove
|
24
operating instructions
Содержание GF40-2
Страница 42: ...42 GF40 Freestanding Pellet Stove 42 warranty ...