Pellet burner GP xx sc                                                                                                 24 

 
6.2.10. USER  MENUS  IN  THE  CONTROL  MODULE  OF  A  PELLET  BURNER  FROM 

SERIES “GP XX SC”. 

 
To enter the burner’s menu press and hold the button “S”. To exit already entered submenu 
press the button “ESC”.  
 

Figure 6.8. To choose a submenu from the burner’s controller press the button “S”.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
6.2.11. MENU “EFFECT LEVEL”. 
 

Figure 6.9. Menu ”EFFECT LEVEL” – choice of a heating output level of a burner from 

series “GP xx sc”. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

This menu is used to choose the heating output level for operation of the burner. The heating 
output levels values achieved by the burner are presented in Table 6.1 

ESC 

COMBUST 5                                            35kW 

75

 

 

 

                           FC: 98% 

 

ESC 

EFFECT LEVEL 

ENTER 

 

                                      EXIT 

 

Содержание GP 18 sc

Страница 1: ...Pellet burner GP xx sc 1 MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE OF AN AUTOMATED PELLET BURNER FROM SERIES GP xx sc http www greenecotherm eu...

Страница 2: ...ring company requires that the technicians performing the above mentioned procedures had successfully passed the product s technical training Manufacturer ZMM Haskovo PLC Address 67 Saedinenie blvd 63...

Страница 3: ...ING TO THE CONSUMED HEATING OUTPUT 22 6 2 8 NOMINAL OPERATION MODE OF THE BURNER 22 6 2 9 OPERATION MODES OF A PELLET BURNER FROM SERIES GP xx sc 22 6 2 10 USER MENUS IN THE CONTROL MODULE OF A PELLET...

Страница 4: ...s regarding environment protection Provisions regarding installation start and adjustment All harmonized provisions of the European Union applicable for your country Please strictly observe the presen...

Страница 5: ...pellet burner from series GP xx sc is equipped with Microprocessor controller managing the burner s modules Display panel with keyboard used to manage the burner s modules Fan for fresh firing air sup...

Страница 6: ...rrent adjustments and to restore the factory settings Passwords for limiting the access to certain levels to parameters for the users and for the servicing staff Availability for operation with temper...

Страница 7: ...tity depends on the pellets ash content and on the burner s operation mode The automated pellet burner from series GP xx sc is designated for utilization of wood pellets complying with the classificat...

Страница 8: ...TS CATEGORY AD DU A 6 0 d A 0 97 DU AB 6 0 d A 0 97 DU B 0 1 6 0 d A 0 97 DU BC 0 1 6 0 d A 0 97 DU C 0 2 0 1 d A 0 97 DU CD 0 2 0 1 d A 0 97 DU D 0 3 0 2 d A 0 97 DU DE 0 3 0 2 d A 0 97 DU E 0 3 d A...

Страница 9: ...3 Sulfur content 2 0 03 0 03 0 04 Nitrogen content 2 0 3 0 3 1 0 Cuprum content mg kg 2 10 10 10 Chromium content mg kg 2 10 10 10 Arsenic content mg kg 2 1 0 1 0 1 0 Cadmium content mg kg 2 0 5 0 5 0...

Страница 10: ...e burner s side and with availability for easy cleaning Emergency temperature sensor for protection from the so called back fire in the main module s pellets feeding pipe Control module which monitors...

Страница 11: ...unting of the burner to a boiler consumer appliance can be performed through bolts or studs and nuts The tightening of the burner has to be performed by a tool for example wrench It is not allowed to...

Страница 12: ...performed in advance regarding the burner s main module position in order to achieve reliable operation easy cleaning maintenance and servicing The burner s main module has to be mounted to the heat...

Страница 13: ...upport bar which is optional equipment to the burner s delivery kit The auger s axis has to be positioned at 45o angle relative to the horizontal plane 5 5 INFORMATION ABOUT INSTALLATION AVAILABILITIE...

Страница 14: ...bserved Maintenance and attendance of the burner must be performed in accordance to the manual for maintenance and operation The operation mode of the system a pellet burner from series GP xx sc and a...

Страница 15: ...on the display panel 6 2 2 CONNECTING AND POWER SUPPLYING OF THE BURNER All activities over the burner s electrical installation adjustments requiring dismounting of cover panels or other components...

Страница 16: ...ernal power supply through its standard plug and to wait until the fuel starts to drop from its top orifice After that it must be connected to the power supply socket of the burner s main module The b...

Страница 17: ...When the assignment is nearly reached the burner s control module decreases its heating output so called modulation of the operation mode If the circulations water temperature decreases the burner res...

Страница 18: ...eaning during operation is switched ON parameter Max comb time This parameter is in Advance menu as the access to it is password protected 6 2 5 OPERATIONAL PARAMETERS FOR ADJUSTMENT OF A PELLET BURNE...

Страница 19: ...n loaded after a few seconds the display panel shows a question whether to start the burner Activate Figure 6 3 Menu for starting a pellet burner from series GP xx sc through inviting question To star...

Страница 20: ...ft corner of the display panel over the button S the water temperature in the hot water boiler degrees Celsius The temperature value is displayed if a water temperature sensor is installed and the opt...

Страница 21: ...e with diameter 6 8mm quality category ENplus A1 ENplus A2 and ENplus B according to standard EN 14961 2 2010 or category A AB B BC C CD E EF see Tables 3 4 and 3 5 The tilting angle between the longi...

Страница 22: ...AL OPERATION MODE OF THE BURNER After completion of the burner s starting process the fuel in the burner s combustion chamber is successfully ignited and the consuming appliance to which the burner is...

Страница 23: ...of 10kW After completing the transition mode the burner transits directly to normal operation mode as presented on Figure 6 7 Figure 6 7 The display shows information about the burner s heating output...

Страница 24: ...6 8 To choose a submenu from the burner s controller press the button S 6 2 11 MENU EFFECT LEVEL Figure 6 9 Menu EFFECT LEVEL choice of a heating output level of a burner from series GP xx sc This men...

Страница 25: ...r short periods of time To enter the menu EFFECT LEVEL press the button under ENTER S To switch to another menu press the button under the arrow on the display The button ESC is used to exit the menu...

Страница 26: ...n can be performed through the control module which submits command for operation of the burner Restoring of the burner s operation can be performed through changing the control module s adjustment 6...

Страница 27: ...er from series GP xx sc To enter the menu MAKE FINAL COMB press the button S and to exit cancel press the button ESC The buttons and are used to scroll through the other menus Figure 6 12 The controll...

Страница 28: ...r and consuming appliance from the ash deposits 6 5 1 EMERGENCY SHUT DOWN OF A PELLET BURNER FROM SERIES GP XX SC During operation of the burner emergency situations might occur as the burner will tra...

Страница 29: ...ions when there is assignment for operation but the control module has switched to secured mode and the burner is not operating The display panel shows a message with the failure code The reason for t...

Страница 30: ...temperature within a range of 75 85o C The reversible temperature sticker condition has to be checked every time when the burner or the consuming appliance have been attended It indicates the current...

Страница 31: ...encies and are not covered by the burner s warranty 6 9 CLEANING AND MAINTENANCE OF A PELLET BURNER FROM SERIES GP XX SC The automatic cleaning system of a pellet burner from series GP xx sc includes...

Страница 32: ...gloves provided by the manufacture company to the end users for easier and safe maintenance of the pellet burner It is necessary to clean the flexible connection tube from the dust separated by the fu...

Страница 33: ...horized technician Opening of the protection cover panel of the burner by unauthorized staff is forbidden Risk from fingers injuries during maintenance and cleaning It is recommended to use proper ind...

Страница 34: ...low quality It is required to change the fuel as its water content is probably higher by the values needed for normal operation of the appliance 5 The fuel ignition is accompanied by abnormal noise I...

Страница 35: ...ormed by servicing technician check the fuses condition and if necessary replace them with new fuses but only from the same type 9 The flame from the burning process is dim and the chimney smokes too...

Страница 36: ...necessary to adjust the appliance s operational parameters ask authorized servicing technicians for consultation and or to perform adjustments 18 Too many slag deposits in the burner s combustion cham...

Страница 37: ...l down Look for servicing assistance 5 14 The temperature sensor has measured a value under 5 o C The circulations water temperature is dangerously low and can freeze Look for servicing assistance to...

Страница 38: ...the temperature stickers 4 TEMP SENSOR LOW The temperature sensor is switched OFF Check connection of NTC sensor 5 PHOTOSENS Photic sensor failure Check the photic sensor condition replace it if neces...

Страница 39: ...Pellet burner GP xx sc 39...

Страница 40: ...transport and or unloading not performed by the manufacturing company Emergencies caused by natural disasters earthquakes fire floods and etc The requirements for installation operation and periodical...