background image

1.

To fit the supplied Xenon lamp you need to loosen the screw (E) securing the

hinged front cover and swing the cover down. The lamp is attached by spring

loaded holders at each end.

2.

Gently locate the lamp into position ensuring good contact at both ends. Take care

not to touch the glass of the lamp, if this does occur clean the lamp with methylated

spirit.

3.

Close the hinged front cover and re-tighten the top retaining screw(E).

DO NOT OVERTIGHTEN,

THIS MAY DAMAGE THE GLASS

Note: The lighting direction cannot be adjusted downwards.

CAUTION:

This unit can become extremely hot whilst in operation, do not touch the unit until it

has had time to cool down. Make sure the worklight is far enough away from any

combustible materials and/or surfaces. Make sure there is adequate ventilation to aid

heat dissipation.

INSTALLER -

Please pass instruction manual

onto the owner of the unit

Please keep these instructions

for future reference.

WEST ROAD . HARLOW
ESSEX . CM

20 2

BG . UK

[email protected]

WWW.GREENBROOK.CO.UK

Is

s

u

e

N
o

:

7

0

2

1

9

2

PART IDENTIFICATION

A. Centre Screw Control

B. Twist Locks

C. Leg Hinges

D. Cable Storage

E. Floodlight Housing

Retaining Screw

FITTING THE LAMP

A

B

C

D

E

Fig

2

Fig

3

Spring Pin

TECHNICAL DATA

Power Source:

110V-50Hz

IP Rating:

IP54

Xenon Lamp:

Class C

400

W max

Power Cord:

H05RN-F 3G1.0

mm

2

Max Stand Height:

2M

Glass Size:

133 x 92 x 4

mm