background image

Thank you for purchasing your new Hercules greenhouse. We recommend you familiarise yourself with the instructions and read all safety 
information before you commence assembly. This instruction manual is also available online at www.greenhousepeople.co.uk             
in our technical help section should you need to reprint it.  Should you require any additional advice you can always call us on 01782 385408. 
 

These instructions are divided into sections; 

B

-base, 

partlists

,

1

-sides, 

2

-front gable, 

3

-rear, 

4

-joining the four sides together, 

5

-roof, 

6

-vent, 

7

-door,        

8

-glazing, 

9

-louvre assembly, 

10

-vent attachment, 

11

-door attachment, 

12

 anchoring down, 

back cover

-packing list.  If you need to contact us for assis-

tance please refer to the relevant section/s or the page numbers bottom middle. 

 

Safety Warning

 



Glass and aluminium can potentially cause injury. Please ensure you wear protective goggles, gloves, headgear and suitable footwear when 
assembling and glazing the building. 



Please remember that glass is fragile and should be handled with extreme care. Always clear up and dispose of any breakages immediately. 



Do not assemble the greenhouse in high winds. 



For safety reasons and ease of assembly, we recommend that this greenhouse is assembled by a minimum of two people.  



Please clear all lying snow from the greenhouse roof as it can cause the roof to buckle or collapse. 

 

Site Preparation

 



When selecting a site for your greenhouse, it is vital that you choose as flat and level an area as possible.  



A concrete or slabbed base will provide the most solid foundation for your greenhouse.   



IMPORTANT: Do 

not

 fix your building down until the building is fully assembled, including glazing.   



Avoid placing your greenhouse under trees or in other vulnerable locations. 



To minimise the risk of wind damage, try to select as sheltered a site as possible, e.g. beside a hedgerow or garden fence. 

 

Additional Considerations

 



Please bear in mind that assembling your greenhouse can be time consuming. You may need to spread the construction over two or more 
days. We recommend that you avoid leaving the building partially glazed.  If you ever have to leave your greenhouse half assembled and not 
anchored down, weigh it down with slabs or bags of sand to stop the wind moving it. 



You will find it helpful to prepare a large, clean and clear area in which to work in. A garage floor or flat lawn area is ideal. 



If you have arranged for someone to install your greenhouse for you, please check that all components are included. Most parts are numbered 
and can be identified by a stamped number (without the ’SY’, ‘HE’, ‘CL’) or removable label. Alternatively, the components can be identified by 
lengths detailed in the packing list (see diagram below). Please also note that 

NOT

 all parts for a specific area will be packed together, i.e. door 

related components are packed together and some are used in main frame construction.   



Anchoring down your greenhouse should be the final stage of construction (including glazing).  



Once installed your greenhouse requires little maintenance, but to maintain the smooth running of 
your door(s) WD40 or similar can be applied to the door wheels and lower door guides.  

 

Guarantee

 



Your new Hercules greenhouse is guaranteed for 10 years against faulty manufacture of the 
framework. This does not include glazing, moving parts, accidental damage or wind damage. 

610mm 

121 

KEY 
SYMBOL 

KEY DESCRIPTION 

 

 

EXTERNAL VIEW 

 

 

 

THINK 

 

THIS SECTION  

RELATES TO  

ANOTHER 

(e.g. 1 to 5) 

 

 

CORRECT 

 

 

DO NOT FIX DOWN! 

 

 

TWIST TO LOCK 

 

 

TIGHTEN 

 

 

DO NOT WET! 

 

 

CUT TO LENGTH 

 

 

INTERNAL VIEW 

Содержание HE-YOR

Страница 1: ...4 Wide ASSEMBLY INSTRUCTIONS ISSUE 1 A mm B mm 4 4 x 4 4 1348 4 4 x 6 4 1968 4 4 x 8 4 2588 4 4 x 10 5 3208 4 4 x 12 5 3828 1320 4 4 x 2 4 728 Model HE YOR ...

Страница 2: ...glazing Avoid placing your greenhouse under trees or in other vulnerable locations To minimise the risk of wind damage try to select as sheltered a site as possible e g beside a hedgerow or garden fence Additional Considerations Please bear in mind that assembling your greenhouse can be time consuming You may need to spread the construction over two or more days We recommend that you avoid leaving...

Страница 3: ...4 x 4 4 1348 4 4 x 6 4 1968 4 4 x 8 4 2588 4 4 x 10 5 3208 4 4 x 12 5 3828 1320 4 4 x 2 4 728 613 SY004 3720 2 SY009 3100 2 SY015 2480 2 SY029 1860 2 SY097 1240 1 3 1 1 1 1 SY098 620 2 SY610 312 2 SY613 100 4 Part No Section Size mm 4 2 4 4 4 6 4 8 4 10 4 12 97 613 ...

Страница 4: ...2 SY077 1504 2 SY089 728 2 SY090 728 2 SY132 304 2 SY133 304 2 SY001 3720 2 SY005 3100 2 SY017 2480 2 SY025 1860 2 SY055 1240 2 SY078 620 2 SY003 3720 2 SY008 3100 2 SY014 2480 2 SY027 1860 2 SY058 1240 2 SY091 620 2 SY021 1585 2 2 SY047 1504 0 2 4 6 8 10 4 SY201 2 SY200 4 SY612 1 SY616 SY615 1 1 615 Part No Section Size mm 4 2 4 4 4 6 4 8 4 10 Page Ref 4 12 SY121 612 1 1 1 2 3 4 SY123 612 1 1 1 2...

Страница 5: ...W 1500 1500 PLASTIC 8 12 16 20 24 28 SYBC C W 2000 2000 PLASTIC SYZ CLIP N A 4 8 12 16 20 24 SY FOAM 15000 FOAM 3 roll 3 roll 4 roll 5 roll 5 roll 5 roll 6 SY651 HE633 SKID 306 2 SY650 HE633 WHEELS 306 2 SY634 306 2 SY630 1730 2 SY652 HE631 SKID 1730 1 SY653 1730 1 HE384 112 2 SY629 795 8 HE571 3800 1 HE583 19 24 HE400 40 2 HE560 N A 2 HE374 1320 1 HE402 1320 1 HE404 N A 2 SY627 612 1 SY614 574 1 ...

Страница 6: ...55 27 25 14 17 8 5 3 1 X 2 X 2 X 2 X 2 X 2 2 X 2 Part No mm Quantity 91 620 2 78 620 2 21 1585 2 91 78 M6 6 M6 6 M6 12 M6 12 M6 16 M6 16 M6 20 M6 20 M6 24 M6 24 M6 2 M6 2 On the 2 long model the sides have no vertical side bar 47 Because of this the sides have little substance and you will find it easier to skip this section 1 until you have built the front section 2 and rear section 3 The sides c...

Страница 7: ...7 47 21 47 PLEASE NOTE THAT 10mm BOLTS ARE USED THROUGHOUT THE MAJORITY OF CONSTRUCTION UNLESS STATED OTHERWISE E g 15mm etc 10mm 15mm ...

Страница 8: ...6 1504 1 77 1504 1 89 728 1 90 728 1 132 304 2 Part No mm Quantity 611 326 2 612 615 1 615 n a 1 616 n a 1 133 304 2 28 8 10mm 15mm M6 34 2 1 612 48 76 77 132 43 89 90 42 133 48 132 133 611 611 76 77 133 48 42 43 2 15mm 615 616 15mm PARTS IN BETA DOOR BOX ...

Страница 9: ...9 42 43 89 90 89 90 48 89 90 48 132 76 77 76 77 611 611 612 615 616 201 42 43 15mm 404 200 ...

Страница 10: ...Part No mm Quantity 42 1734 1 43 1734 1 48 1489 2 59 1236 1 62 1216 1 Part No mm Quantity 63 1216 1 76 1504 1 77 1504 1 89 728 1 90 728 1 30 30 M6 2 1 48 42 43 59 48 76 77 62 43 89 90 42 63 48 59 76 77 59 ...

Страница 11: ...11 42 43 89 90 63 63 89 90 76 77 48 62 62 89 90 201 200 ...

Страница 12: ...12 ...

Страница 13: ... Drill centrally between two vertical glazing bars for neatness it is not essential to drill every section Make sure the bolt head does NOT interfere with the line of the glass Cills should be drilled 18mm from the inside vertical face to avoid the front glass face Do NOT anchor the structure to the ground until the end M6 CROP 15mm 615 616 SY159 ...

Страница 14: ...y 26 1860 1 92 741 4 93 636 1 135 894 4 1046 375 2 18 2 Part No mm Quantity 88 620 1 92 741 0 81 617 1 135 894 0 2 1 1 2 2 3 3 4 4 4 Part No mm Quantity 57 1240 1 92 741 2 85 628 1 135 894 2 1046 375 1 9 135 135 92 92 135 21 ...

Страница 15: ... 12 2480 1 92 741 6 93 636 2 135 894 4 1046 375 3 26 12 Part No mm Quantity 2 3720 1 92 741 10 93 636 4 135 894 4 1046 375 5 42 10 Part No mm Quantity 6 3100 1 92 741 8 93 636 3 135 894 4 1046 375 4 36 X 2 M4 X 4 81 85 93 1046 ...

Страница 16: ...16 127 121 121 127 610 x 457 M6 10mm X 2 X 2 X 4 M4 X 2 M4 X 2 X 1 1000mm Part No mm Quantity 121 612 1 123 612 1 127 457 2 CAPPING CUT TO 436mm X 2 ...

Страница 17: ...17 123 610 x 457 ...

Страница 18: ...52 1730 1 384 2 629 8 571 1 4m 583 24 SYBOLM6X11 4 SYNUTM6 4 653 1730 1 E 249 x 805 4 OF 630 630 634 634 629 629 629 629 650 651 START FINISH 630 630 652 653 650 651 571 571 INSERT GLASS COMPLETE 634 E 249 x 805 E 249 x 805 629 629 629 629 E 249 x 805 E 249 x 805 650 651 ...

Страница 19: ...19 630 634 629 650 651 652 630 583 384 630 E 249 x 805 E 249 x 805 583 630 583 630 571 650 ...

Страница 20: ...ally the glass just sits directly onto the aluminium cills in the sides Remove the white paper on the foam before it gets wet as it is difficult to re move i e it comes off in small pieces e g SYBC C W 1500 GLASS GLASS GLASS GLASS CAPPING NEEDS TO BE CUT TO LENGTH AND AROUND LOUVRES IT ONLY NEEDS TO GO WHERE GLASS IS ADJACENT ...

Страница 21: ...5 6 7 8 B 610 x 457 1 2 3 4 U 610 x 312 1 2 3 4 M 610 x 904 1 2 D 610 x 153 1 2 L 573 x 100 5 C 305 x 1197 4 E 249 x 805 4 610mm ROSEPS 3 2 NEED TO BE CUT IN HALF 10 R S S S S B U C C P J J P 610 35 245 G 610 448 233 J 532 324 305 S R E E E E LOUVRE MUST GO BACK CENTRE ON THE 4X2 4X4 MODELS R ...

Страница 22: ...22 Part No HE583 SYBOL M6X11 CROP SYNUT M6 Detail Length mm 19 11 N A Quantity 4 4 4 HE583 HE583 HE583 PINCH ALL GLASS RETAINERS x 10 BEFORE GLAZING 573 x 100 panes x 5 ...

Страница 23: ...23 123 81 85 93 81 85 93 81 85 93 81 85 93 ...

Страница 24: ...24 612 614 374 402 374 Part No mm Quantity 402 1320 1 627 612 1 SYBOLM6X11 7 SYNUTM6 7 Part No mm Quantity 374 1320 1 614 574 1 404 627 CENTRE 627 10mm CENTRE PUSH 616 615 614 ...

Страница 25: ...5 402 650 374 Part No mm Quantity 300 n a 2 SYBOLM6X11 4 SYNUTM6 4 707 INSERT DOORS Part No mm Quantity 400 n a 2 560 n a 2 SYNUTM6 2 400 560 133 402 DRILL 7mm HOLE AVOIDING GLASS NOT SUPPLIED 300 89 90 ...

Страница 26: ...26 O7mm Part No mm Quantity 02 1825 NARROW HEAD 2 SYSCR2 10 SYRAWL 12 300 10 SYBOLM6X11CROP 10 SYNUTM6 10 02 1825 NARROW HEAD SYRAWL 615 616 SYSCR2 SYRAWL 300 SYSCR2 SYRAWL ...

Страница 27: ... SMALLS 2 HE YOR FRAME SMALLS INC BASE Part No Section 2 4 6 8 10 12 SYBOLM6 X11 91 103 119 131 145 155 SYBOLM6 X15 8 SBOLM6 X11CROP 22 21 SYNUTM6 121 132 147 159 173 183 SYZCLIP 4 8 12 16 20 24 HE300 C 10 SY613 C 4 SY201 C 2 SY200 C 4 SYSMA VENT C VENT SMALLS 1 2 3 4 SY STAY C 1 2 3 4 SYSCR2 10 02 1825 2 SYRAWL 12 D250B 100 121 132 147 159 173 183 SY159 C 10 20 ...

Страница 28: ... building BOX PACKED BY 1 drop door smalls pack CASMA1 SYBC C W 1210 PLASTIC 1210 8 12 16 20 24 28 SYBC C W 1500 PLASTIC 1500 8 12 16 20 24 28 SYBC C W 2000 PLASTIC 2000 6 6 6 6 6 6 No mm 2 4 6 8 10 12 1 3720 2 2 3720 1 3 3720 2 5 3100 2 6 3100 1 8 3100 2 12 2480 1 14 2480 2 17 2480 2 21 1585 2 2 4 4 4 4 25 1860 2 26 1860 1 27 1860 2 42 1730 2 2 2 2 2 2 43 1730 2 2 2 2 2 2 47 1504 0 2 4 6 8 10 48 ...

Отзывы: