background image

__________________________________________________________________________________ 

Green-GO Bridge X   – Quick Start Guide

 

 

Connection 

à

 

Set up this port as the Passive side of the connection. 

Password    

 

à

 

Set up a password for this connection. The  

 

 

 

 

password needs to be identical on both sides of the 

 

 

 

 

connection. and is always 8 characters long. 

Generate Password 

à

 

Automatically generate a random 8-character 

 

 

 

 

password 

Local Port   

 

à

 

Set up a UDP port for the connection. This port 

 

 

 

 

needs to be the same on both sides of the  

 

 

 

 

connection. A different and free port needs to be 

 

 

 

 

used for each connection 

SndBuf 

 

 

à

 

Set up the size of the audio packages being sent 

 

 

 

 

out from this port. a connection with high jitter in 

 

 

 

 

latency needs a larger Buffer 

RecvBuf   

 

à

 

Set up the size of the buffer for the incoming 

 

 

 

 

audio packages A connection with high jitter in 

 

 

 

 

latency needs a larger Buffer 

Save   

 

 

à

 

Save all changes made on this port connection 

Cancel 

 

 

à

 

Discard all changes made on this port connection 

Configuration cloning 

All devices in the local Green-GO network need to have the same configuration to be able to 
communicate with each other. 

Clone Config  

à

 

Clone a configuration file from the network

 

 

 

Configuration File A 

à

 

Load configuration file A 

 

 

Configuration File B 

à

 

Load configuration file B 

 

 

etc. 

 

 

Factory Default     

à

 

Load the factory default configuration file 

Setup internal Network  

Here you can modify the Network settings of the Internal Green-GO network. 

Dynamic 

à

 

Select the connection mode. 

 

ON 

à

 

Use a dynamic IP. If a DHCP server is on the network this will supply an  

 

 

IP address to the device. If there is no DHCP server the device will self-assign 

 

 

a Link local IP. 

 

OFF 

à

 

Use a static IP 

 

 

IP address   

à

 

Set the IP address to be used 

 

 

Netmask   

à

 

Set the netmask to be used 

 

 

Gateway   

à

 

Set the gateway to be used 

Save   

à

 

Save the current network setup 

Cancel 

à

 

Discard current network changes 

 

Содержание Bridge X

Страница 1: ...Bridge X Quick Start Guide...

Страница 2: ...Device or network anywhere in the world It is able to route up to 4 Users or Groups to a remote location 4 bridge ports available Bridge mode to allow a remote connection to your network Remote mode t...

Страница 3: ...p a bridge port Here you can set up all Bridge X ports Port x yyyy Mode Off This Bridge port is switched off Mode Group Bridge Set this port to Group Bridge mode In group bridge mode you can transfer...

Страница 4: ...p to another port Enabling this will allow you to connect the same group to 3 or more locations without the need to make a bridge connection between all locations Don t route An incoming Group can t b...

Страница 5: ...on both sides of the connection A different and free port needs to be used for each connection SndBuf Set up the size of the audio packages being sent out from this port A connection with high jitter...

Страница 6: ...ter in latency needs a larger Buffer Save Save all changes made on this port connection Cancel Discard all changes made on this port connection Configuration cloning All devices in the local Green GO...

Страница 7: ...ave this menu Backlight Set the time out of the display Always on or a range from 10 seconds through 4 hours Display Set the Intensity of the display Device information Info Shows general information...

Страница 8: ...nstructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or fire...

Страница 9: ...idge X Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35 EU E...

Отзывы: