Green Bit DactyScan84c Скачать руководство пользователя страница 11

Installation 

 

  

DactyScan84c

 

Operator’s Manual

 

Rev. 1.0 July 2012 

11 

 

 5   Installation 

This chapter explains how to install the Green Bit DACTYSCAN84C device. 
 

 

NOTE

:

 

Before connecting the DACTYSCAN84C  device to the 
Personal Computer, the software driver must be 
installed. Consult the 

MultiScan SDK

 software manual.

 

 5.1   PC Requirements  

Prior  to  installation,  check  that  the  Personal  Computer  is  suitable  for  the 
device.  For  the  characteristics  of  the  Personal  Computer,  refer  to  the  table 
below: 

 

Minimum requirements 

Recommended 

Processor 
 

Pentium IV @2,8 GHz or 
equivalent 

Intel ® Core 2 Duo @1.8GHz 
or equivalent 

RAM 

256 MByte 

512 Mbyte 

Interface 

USB 2.0 

USB 2.0 

Operating system 

Windows 2000 ® SP3 
Windows XP ® SP1 (32 bit) 
Windows XP ® SP1 (64 bit) 
Windows 2003® Server SP1 
(64 bit) 
Windows Vista (32 bit) 

Windows XP ® SP2 (32 bit) 
Windows 7 ® (32 bit) 

 

 

NOTE

:

 

The requirements indicated above are valid for desktop 
PCs. For portable PCs, correct functioning is not 
guaranteed as their performance level is lower than 
that of desktop PCs with the same characteristics. 
Therefore, before using the device with a portable 
computer, it is advisable to run tests

.

 

 

 

 5.2   Packaging 

Check  that  the  packaging  of  the  DACTYSCAN84C  is  undamaged,  without 
evident  signs  of  impacts,  tears  or  traces  of  damp.  If  one  or  more  of  these 
conditions  is  not  complied  with,  contact  the  assistance  service.  The  supply 
includes the following parts: 

 

Green Bit DACTYSCAN84C electronic device. 

 

Green  Bit  USB  2.0  High  Speed  cable  with  disturbance  suppression 

ferrite 

Содержание DactyScan84c

Страница 1: ...c Rev 1 0 July 2012 Produced by Green Bit S p A Via Rivalta 9 10095 Grugliasco TO Tel 39 011 7703811 Fax 39 011 7703880 info greenbit com DactyScan DactyScan DactyScan DactyScan84 84 84 84c c c c Operator s Manual ...

Страница 2: ...n _________________________________________________ 8 4 3 Technical characteristics ________________________________________ 9 4 3 1 Power supply ___________________________________________________ 9 4 3 2 Operating and storage conditions ___________________________________ 9 4 3 3 Physical characteristics ___________________________________________ 9 4 3 4 Four slaps and two thumbs acquisition __...

Страница 3: ...ange of destination or ownership 1 1 Warnings The following graphic symbols have been used to highlight certain parts of the text considered to be particularly important DANGER This symbol indicates dangerous situations that if proper precautions are not taken may cause serious risks to personal health and safety WARNING This symbol indicates dangerous situations which if proper precautions are no...

Страница 4: ...ic shock never carry out maintenance or configuration operations during a storm Check that the connection cables do not impede or obstruct the transit of persons WARNING Never attempt to operate on the device if you are not a trained maintenance engineer Always consult the manual All device cleaning operations must be carried out with the device OFF and disconnected from the PC Never insert any ob...

Страница 5: ...distance from the DACTYSCAN84C device Radiation If the DACTYSCAN84C device is close to receivers transmitters modify the direction of the antenna Dedicated circuits Connect the DACTYSCAN84C device on separate power lines from other devices with high electric noise such as for example conditioners 2 3 Environmental protection European Union This symbol applied to the product or packaging indicates ...

Страница 6: ...This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with th...

Страница 7: ...tampered with or repaired by third parties not authorized by Green Bit S p A Replacement of parts under warranty shall not in any case extend the terms thereof Alterations modifications of performance or the application of new equipment to the device to which this manual refers without the written authorization of Green Bit S p A are absolutely forbidden Damage caused by negligence neglect misuse ...

Страница 8: ...ith IAFIS IQS regulations FBI CJIS RS 0010 appendix F 4 2 Identification Product identification data are indicated on an adhesive label applied to the back of the device the label is shown in the figure below This data must be indicated in the case of requests for assistance or the supply of spare parts Description of label Green Bit logo Name of the product Manufacturer Place of construction The ...

Страница 9: ...ice is powered throught the USB 2 0 interface 4 3 2 Operating and storage conditions Parameter Description Min Max Tst Storage temperature ºC 20 60 Top Operating temperature ºC 0 50 RH Relative humidity without condensation 10 90 4 3 3 Physical characteristics Width 148 mm Height 148 mm Dimensions Depth 152 mm Color Computer Gray RAL 9018 Weight 1400 g ...

Страница 10: ...t and brightness adjustment Automatic Elimination of latent print Automatic 4 3 5 Rolled finger acquisition Quality Standard of the image Compliant with IAFIS IQS regulations FBI CJIS RS 0010 appendix F Resolution 500 dpi 1 Dynamics 8 bit 256 shades of gray Image area 1 6 x 1 6 40 6 x 40 6 mm Size of image 800 x 800 pixels Scanning speed 25 fps Capture of rolled fingerprint Automatic Max speed rol...

Страница 11: ... 2 0 Operating system Windows 2000 SP3 Windows XP SP1 32 bit Windows XP SP1 64 bit Windows 2003 Server SP1 64 bit Windows Vista 32 bit Windows XP SP2 32 bit Windows 7 32 bit NOTE The requirements indicated above are valid for desktop PCs For portable PCs correct functioning is not guaranteed as their performance level is lower than that of desktop PCs with the same characteristics Therefore before...

Страница 12: ... those furnished by Green Bit does not guarantee compliance with current Directives and legislation 5 3 External appearance The device is housed in an ergonomically designed case with on the surface one optical as shown in the photos A B A Optical scanner 3 2 x 3 B Graphical user interface C C USB 2 0 connector ...

Страница 13: ... the DACTYSCAN84C device is ready for use NOTE Image acquisition and quality control is carried out and checked by specific application software for further information refer to the MultiScan SDK software documentation and the user manual of the application for installation and use ...

Страница 14: ... the scanner need not be perfectly clean as a slight film of dust grease or moisture is compensated electronically it is advisable to clean the acquisition surface of the scanner only in the case of evident signs of dirt or if highlighted by the diagnostics of the device For routine cleaning of the scanner use the specific Cleaning Accessories Kit provided Proceed as follows 1 Take a tissue for cl...

Страница 15: ...Green Bit S p A Via Rivalta 9 10095 Grugliasco TO Tel 39 011 7703811 Fax 39 011 7703880 info greenbit com ...

Отзывы: