![GREEN BANK LB24250 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/green-bank/lb24250/lb24250_user-manual_2260898007.webp)
LiFePO4 Battery System for Households
LiFePO4 Battery System for Households
4. OPERATION
Once the batteries are connected well, simply press On/Off button to enable the output of the battery pack.
1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before
enable output. The LED will show the SOC.
2.Switch off: press and hold On/Off button for 3 seconds, the battery will shut down directly.
Description for Communication port
4.1 Switch On / Off
Picture PIN Description
1
2
3
4
5
6
7
8
Trigger-GND
Trigger-VCC
NC
COMM-GND
RS485-B
RS485-A
CANL
CANH
The SOC of the battery is shown by the LED
4.2 Description for LED
DIP SWITCH
1-4
5
Communication Address
Termination Resister
Note: The battery need to be fully charged for at least once in one month to ensure the accurate SOC
calculation.
100% 75% 50% 25% Flashing SOC<10%
48V
Front view
10
09
4.3 ON / OFF or SOC Led (Mode or SOC)
BATTERY
MODE
ON/OFF
SOC
REMARK
GREEN
LED RED
LED
LED1
LED2
LED3
LED4
POWER
OFF
OFF
OFF
OFF
OFF
OFF
OFF
POWER
ON
OFF
ON
ON
ON
ON
ON
STANDBY
OFF
OFF
SOC
SOC<10%(DEFAULT ):
LED1
FLASH
NORMAL
ON
OFF
RUNNING/SOC
SOC<10%(DEFAULT ):
LED1
FLASH
DISCHARGE
ON
OFF
SOC
SOC<10%(DEFAULT ):
LED1
FLASH
CHARGE
FLASH
OFF
RUNNING
LOW
POWER
FLASH
OFF
OFF
FAULT
OFF
ON
ON
OFF
OFF
OFF BATTERY
VOLTAGE
HIGH
OFF
ON
OFF
OFF BATTERY
VOLTAGE
LOW
ON
ON
OFF
OFF CELL
VOLTAGE
HIGH
OFF
OFF
ON
OFF CELL
VOLTAGE
LOW
ON
OFF
ON
OFF CHARGING
CURRENT
HIGH
OFF
ON
ON
OFF DISCHARGING
CURRENT
HIGH
ON
ON
ON
OFF BMS
TEMPERATURE
HIGH
OFF
OFF
OFF
ON BMS
TEMPERATURE
LOW
ON
OFF
OFF
ON CELL
TEMPERATURE
HIGH
OFF
ON
OFF
ON CELL
TEMPERATURE
LOW
ON
ON
OFF
ON CURRENT
SENSOR
ABNOMAL
Sw1 SW2 SW3 SW4 Remarks
0 0 0 0 means ID=0,communication address is0x00/0x10
③
1 0 0 0 means ID=1,communication address is0x01
④
0 1 0 0 means ID=2,communication address is0x02
1 1 0 0 means ID=3,communication address is0x03
0 0 1 0 means ID=4,communication address is0x04
1 0 1 0 means ID=5,communication address is0x05
0 1 1 0 means ID=6,communication address is0x06
1 1 1 0 means ID=7,communication address is0x07
0 0 0 1 means ID=8,communication address is0x08
1 0 0 1 means ID=9,communication address is0x09
0 1 0 1 means ID=10,communication address is0x0A
1 1 0 1 means ID=11,communication address is0x0B
0 0 1 1 means ID=12,communication address is0x0C
1 0 1 1 means ID=13,communication address is0x0D
0 1 1 1 means ID=14,communication address is0x0E
1 1 1 1 means ID=15,communication address is0x0F
DIP switch SW5 Description
②
SW5
1
0
Remarks
means disconnect
120Ω resistor
means connect
120Ω resistor
Remark
①
: 1 in SW1-SW5 indicates ON status, and 0 indicates OFF status.
Remark
②
: When multiple battery packs communicate, the last battery pack SW5 needs to be in the ON
status, otherwise the communication may have interference.
Remark
③
: When the battery pack ID is set to 0, it means stand-alone operation, and it is not necessary to
detect whether the parallel condition is satisfied
⑤
Remark
④
: When the battery pack ID is set to 1-15, it means that the parallel operation is required, and it is
necessary to detect whether the parallel condition is satisfied
⑤
Remark
⑤
: The parallel condition is that the difference between the battery voltage of the local battery and
all the battery pack voltages is <3V, otherwise wait until the condition is satisfied
DIP switch SW1-SW4 Description
①
4.4 DIP switch SW1-SW4 Description